Mk ii ptz dome network camera / ptz dome network camera / mk ii ptz dome network camera (164 pages)
Summary of Contents for Axis Q6042-S PTZ
Page 1
INSTALLATION GUIDE AXIS Q60-S Series AXIS Q6042-S PTZ Dome Network Camera AXIS Q6044-S PTZ Dome Network Camera AXIS Q6045-S PTZ Dome Network Camera...
Page 2
Search by product, category, or phrase document. Please inform your local Axis office of any • report problems to Axis support staff by logging in to inaccuracies or omissions. Axis Communications AB cannot your private support area be held responsible for any technical or typographical errors •...
Page 3
(RoHS). China This product complies with the requirements of the legislative act Administration on the Control of Pollution Caused by Electronic Information Products (ACPEIP). Contact Information Axis Communications AB Emdalavägen 14 223 69 Lund Sweden...
AXIS Q60-S Series Safety Information Read through this Installation Guide carefully before installing the product. Keep the Installation Guide for future reference. Hazard Levels DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Battery The Axis product uses a 3.0 V BR2032 lithium battery as the power supply for its internal real-time clock (RTC). Under normal conditions this battery will last for a minimum of five years. Low battery power affects the operation of the RTC, causing it to reset at every power-up. A log message will appear when the battery needs replacing.
WARNING • Risk of explosion if the battery is incorrectly replaced. • Replace only with an identical battery or a battery which is recommended by Axis. • Dispose of used batteries according to local regulations or the battery manufacturer's instructions.
AXIS Q60-S Series Installation Guide This Installation Guide provides instructions for installing AXIS Q6042-S/Q6044-S/Q6045-S PTZ Dome Network Camera on your network. For other aspects of using the product, see the User Manual available at www.axis.com Installation Steps 1. Make sure the package contents, tools and other materials necessary for the installation are in order.
AXIS T8008 PS12 Power Supply • AXIS T8310 Video Surveillance Control Board • AXIS T90A Illuminators • Installation Display For information about available accessories, see www.axis.com Hardware Overview Mounting hole for sunshield (3x) Pressure relief valve Multiconnector Hook for safety wire...
Page 11
AXIS Q60-S Series Guide hole Inlet valve Mounting hole (3x) Part number (P/N) & Serial number (S/N) SD card slot (SDHC) 10 Status LED indicator 11 Control button Dome Cover Dome bracket screw T25 (4x) Dome cover Rubber gasket Rubber gasket...
AXIS Q60-S Series Multi-Connector Cable The supplied multi-connector cable is required in order to maintain the camera’s IP rating. Connect the multi-connector cable to the camera’s multi-connector and to the connectors in the supplied media converter switch, see page 10.
Page 15
AXIS Q60-S Series NOTICE NOTICE NOTICE The product shall be connected using a shielded network cable (STP) or an optical fiber cable. All cables connecting the product to the network shall be intended for their specific use. Make sure that the network devices are installed in accordance with the manufacturer’s instructions.
When a signal is received the state changes and the input becomes active (shown under System Options > Port & Devices > Port Status). I/O connector (internal) - 2–pin I/O terminal block. Specifications Operating Conditions The Axis product is intended for outdoor use. Product Temperature Humidity Classification...
Page 17
AXIS Q60-S Series Media Converter Switch Connectors Power connector (DC input) 2-pin terminal block for power input. Function Notes Specifications DC input Ground 12 V DC Power in from power Max load = 7 A supply (sold separately) 12.0–13.2 V DC,...
AXIS Q60-S Series I/O terminal connector (external) 6-pin terminal blocks for: • Digital Input/Output • Power (DC output) • Ground (GND) Function Notes Specifications 1, 4, 6 Ground DC output Power out 12 V DC, 50 mA Configurable Digital input...
AXIS Q60-S Series The Axis product can be installed with the cables routed through or along the wall or roof. Read all the instructions before installing the product. Some installation steps would benefit from being completed together because they require removal of the dome cover.
AXIS Q60-S Series 3. Attach the dome cover to the top cover and tighten the screws (torque 3.2 Nm). NOTICE NOTICE NOTICE To prevent corruption of recordings, the SD card should be unmounted before it is ejected. To unmount, go to Setup > System Options > Storage > SD Card and click Unmount.
Page 21
For information about regulatory requirements, see Regulatory Information, on page 2 . Important Axis can only guarantee full functionality with the supplied media converter switch. No other devices are supported. 1. Make sure the mains supply is switched off.
Page 22
AXIS Q60-S Series 5. Leave the braided shield intact, but cut off 30 mm (1.18 in) of the outer foil shield. 6. Fold back the leftover outer foil shield and twist the braided shield into a coil. 7. Cut off about 7–8 mm (0.27–0.32 in) of the Ethernet wire foil shields.
Page 23
AXIS Q60-S Series Power wire (red) Digital I/O wire (blue) Ethernet wire (green/white) Ethernet wire (green) Ethernet wire (orange/white) Ethernet wire (orange) Digital I/O wire (yellow) Ground wire (black) Power wire (red) 10 Ethernet wire foil shield (2x) 11 Outer foil shield 12 Braided shield coil 9.
Page 24
AXIS Q60-S Series Power wire (red) Digital I/O wire (blue) Ethernet wire (green/white) Ethernet wire (green) Ethernet wire (orange/white) Ethernet wire (orange) Digital I/O wire (yellow) Ground wire (black) Power wire (red) 10 Power connector (DC output) 11 Ethernet connector (internal)
Page 25
AXIS Q60-S Series 11. Make sure the clamp is in place, insert the braided shield coil into the ground clip and tighten the screws. NOTICE NOTICE NOTICE • The shields and the clamp surfaces shall be in full contact with each other so that the multi-connector cable is grounded.
Page 26
AXIS Q60-S Series 13. If applicable, connect an I/O device to the external I/O connector. 14. Connect the power cable (DC input) to the power connector (DC input) via the terminal block plug. 15. Attach the ground wire to the ground screw.
1. Install the selected bracket (sold separately) according to the instructions supplied with the bracket. If drilling is required, make sure to use drill bits, screws, and plugs that are appropriate for the material. See www.axis.com for information on available mounting accessories.
Page 28
AXIS Q60-S Series Mounting example (wall bracket sold separately) Safety wire 4. Remove the protection cap covering the multi-connector on the camera. 5. Connect the multi-connector cable to the connector on the camera. Use the alignment indicators to find the correct position.
Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP address, to the factory default values. Note The installation and management software tools are available on the CD supplied with the product and from the support pages on www.axis.com/techsup...
Further Information The User Manual is available at www.axis.com Visit www.axis.com/techsup to check if there is updated firmware available for your network product. To see the currently installed firmware version, go to Setup > About. Visit Axis learning center www.axis.com/academy for useful trainings, webinars, tutorials and guides.