7) PC side: Double-click "Special (MCU/IMC2/Facsimile)" to develop
its sub trees, and select "Upload EEP-ROM Data Area" in the sub
trees.
8) PC side: Enter a desired file name, and select "Save."
9) PC side: When upload is completed, the complete message is dis-
played.
With the above procedure, the EEPROM data acquisition is completed.
Data acquired by the EEPROM data acquisition procedure are saved
in a file with extension of .eep.

4. Serial number setting

The serial number is set to the PC which is used for downloading. Set-
ting is required once only, and there is no need to set again when
rebooting the program.
1) PC side: Boot "Mainetenance.exe" and select "JUGARD2" in the
"Select Model" menu.
(Only to set the serial number, the PC should not be connected to
the machine.)
2) Select "Option"
3) Enter optional values to "Product Code" and "ID Code" on the menu
box.
Product Code (P): Enter number (0 – 99)
ID Code(I):
After completion setting, press [OK] key.
4) The PC number (serial number) has been assigned.

5. Installing procedures

<USB integration maintenance program installation>
Driver installation is made on plug-and-play.
<Installation on Windows XP>
1) Main unit side: Press and hold [CA] key and [LEFT(V)] key, and turn
on the power simultaneously. (Check that "DOWNLOAD MODE" is
displayed on the LCD of the operation panel.
2) Connect the machine and the PC with a USB cable.
AL-1651CS ELECTRICAL SECTION 14 - 4
"Serial Number Setting" on the menu bar.
Enter the product code of "3."
Enter number (0 – 99)
Assign an individual code to each PC uses
"MaintenanceTool.exe."