26
43
Side void amount setting
(SIDE VOID)
62
Energy-save mode copy
lamp setting (C-LAMP E-S)
64
Heater control setting in
scanner mode (S-MODE
HEATER)
30
01
Paper sensor status display
(P-SENSOR)
[Function]
When this test command is executed, the currently set code of the side void quantity is displayed (ini-
tial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side 2.0mm))
9
Code
Setting
0
0 mm
1
0.5 mm
2
1.0 mm
3
1.5 mm
4
2.0 mm
5
2.5 mm
6
3.0 mm
7
3.5 mm
8
4.0 mm
9
4.5 mm
10
5.5 mm
When the adjustment value is increased by 1, the side void is changed as follows:
Side void adjustment: The side void is increased by 0.5mm. (The side void of "Set value x 0.5mm"
is made.)
[Operation]
1) Initial display
26-43 SIDE VOID
4( 0-10)
[Function]
Used to set half-ON /OFF of the copy lamp in the pre-heat mode.
When this test command is executed, the current set code number is displayed. Enter the desired
code number and press [ENTER/START] key to save the setting.
Code number
0
Copy lamp OFF
1
Copy lamp half-ON
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the code number of the current heater control setting is dis-
played. Enter the code number corresponding to the desired heater control setting and press
[ENTER/START] key to save the setting.
Code number
Heater control setting
0
Heater control OFF
1
Heater control ON
[Operation]
The operation is similar to test command 21-01.
[Function]
The paper sensor status is displayed on the LCD.
Sensor
Paper exit sensor
No. 1 tray paper width sensor
No. 2 tray paper width sensor
Paper entry sensor
Duplex sensor
No. 2 tray paper feed sensor
New drum cartridge sensor
Since the manual paper feed sensor is a single bypass sensor, its status is not displayed.
[Operation]
1) Initial display
30-01 P-SENSOR
AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 13
Details of function/operation
Remark
4
Default
2)
/10KEY]
26-43 SIDE VOID
5( 0-10)
2) [ /10KEY]
26-43 SIDE VOID
3( 0-10)
Setting
Display item
OFF
ON
Display item
OFF
Default (Only for Europe)
ON
Default (Only for other than Europe)
Display item
POD
PD1
PD2
PPD1
PPD2
PPD3
DRST
2) When sensor ON
30-01 POD
PD1
PD2
PPD1 PPD2 PPD3 DRST
3) [ENTER/START]
26-43 SIDE VOID
5( 0-10)
Remark
Default
Remark