ELECTRICAL COMPONENTS
The electrical components are located inside the power base. The charger power cord receptacle, ammeter, main circuit
breaker, controller connector, and charger inhibit connector are located on the electronics tray. See figure 6.
Charger Power Cord Receptacle: This is where the charger power cord plugs into the optional onboard battery charger.
Ammeter: The ammeter displays the onboard charger's current output in amps.
Controller Connector: This is where the controller connects to the power base.
Charger Inhibit Connector: The charger inhibit enables the optional onboard battery charger to disable the controller
during charging.
Main Circuit Breaker: The main circuit breaker is a safety feature built into your power chair. When the batteries and
motors are heavily strained (e.g., from excessive loads), the main circuit breaker will trip to prevent damage to the motors
and the electronics. If the circuit trips, allow your power chair to "rest" for approximately one minute. Then, push in the
circuit breaker button, turn on the controller power, and continue normal operation. If the main circuit breaker continues to
trip repeatedly, contact your authorized Pride provider.
CHARGER POWER CORD RECEPTACLE
AMMETER
MAIN CIRCUIT BREAKER
CHARGER INHIBIT CONNECTOR
CONTROLLER CONNECTOR
Figure 6. Electronics Tray