7.
To remove the recirculation pump:
a) Loosen the clamps and pull the recir-
culation hoses off the pump. Note that
there is a tab on the outlet connector
that fits into a slot in the hose.
b) Remove the three 5/16˝ hex-head
screws from the recirculation pump
and remove the pump from the tub.
Slide Pump Hose
Onto Connector With
Tab Into Hose Slot
Recirculation
Inlet Hose
Outlet Hose
Pump
Screws
c) Disconnect the 2-wire connector from
the recirculation pump terminals.
4-14
Wire Connector