Whirlpool Cabrio WTW6200S User Manual page 45

Cabrio automatic washer
Hide thumbs Also See for Cabrio WTW6200S:
Table of Contents

Advertisement

f)
Loosen the clamps and remove the three
hoses going to the water inlet/dispenser
valve assembly.
Water Inlet/Dispenser Valve Hoses
g)
Lower the cabinet top.
h)
Slide the power supply cord strain relief
out of the housing and move it away from
the valve assembly.
i)
Remove the two hex-head screws from
the water inlet/dispenser valve assem-
bly, and remove the assembly from the
washer.
Strain Relief
Screw
Water Inlet/Dispenser Valve Assembly
5.
Strain Relief
6.
Screw
P2
P1
4-5
To remove the power supply cord:
a) Disconnect the power supply cord con-
nector from the machine/motor control.
b) Remove the hex-head screw from the
green ground wire.
c) Slide the power supply cord strain re-
lief out of the housing and remove the
cord.
Ground Screw
To remove the machine/motor control
& pressure transducer:
a) Disconnect the nine wire connectors
from the control.
b) Pull the pressure transducer tube off
the fitting on the control.
c) Remove the hex-head mounting screw.
d) Lift the front of the control, slide it out
from under the clips at the back, and
remove it.
P4
P13
P5
Machine/Motor
Control
Pressure Transducer Tube
Power Supply
Cord Connector
P9 P10
P12
P11
Screw

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents