Function
Range
Resistance
400
4k
40k
400k
4M
40M
Capacitance
40nF
400nF
4µF
40µF
100µF
Frequency
5.000Hz
50.00Hz
500.0Hz
5.000kHz 0.001kHz
50.00kHz 0.01kHz
500.0kHz 0.1kHz
5.000MHz 0.001MHz
10.00MHz 0.01MHz
Sensitivity: 0.8V rms min. <100kHz; 5Vrms min > 100kHz.
Duty Cycle
0.1 to 99.9% 0.1%
Temp
-4 to 1382°F 1°F
(type-K)
-20 to 750°C 1°C
Temp
-4 to 518°F
(IR)
-20 to270°C 1°C
NOTE: Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital
converter.
Resolution
0.1
0.001k
0.01k
0.1k
0.001M
0.01M
0.01nF
0.1nF
0.001µF
0.01µF
0.1µF
0.001Hz
0.01Hz
0.1Hz
Pulse width: 100 s - 100ms, Frequency: 5Hz to 150kHz
1°F
8
Accuracy
±(0.8% reading + 4 digits)
±(0.8% reading + 2 digits)
±(1.0% reading + 2 digits)
±(3.0% reading + 5 digits)
±(5.0% reading + 7 digits)
±(3.0% reading + 5 digits)
±(3.5% reading + 5 digits)
±(5.0% reading + 5 digits)
±(1.5% reading + 5 digits)
±(1.2% reading + 2 digits)
±(1.5% reading + 4 digits)
±(1.2% reading + 2 digits)
±(3.0% reading + 3 digits)
(probe accuracy not included)
±2.0% reading or ±2°C, ± 4 °F