Sbcg Internal Wiring Diagram - Westerbeke 3.5KW SBCG-60Hz Operator's Manual

60hz and 50hz single phase gasoline geberator
Table of Contents

Advertisement

SBCG DESCRIPTION and TROUBLESHOOTING
REFER ALSO TO THE SPECIFICATION PAGE
BRUSHLESS CAPACITOR
GENERATOR
Engine RPM at 2200
generator turns at
3600 (60Hz) 3000 (50Hz)
60Hz 120 Volts 30. Ampsfor SBCG
50Hz 230 Volts
is
Amps for SBCG
TROUBLESHOOTING CHART
Refer to the following page for the BCG Internal Wiring
Schematic and the BCG Winding Resistances.
CAUSE
FAULT
No AC Output Voltage
1. Shorted Stator.
Residual Voltage
Line - Neutral at
No Load (s-a
VAC)
Low AC Output
Voltage 60 -100 Volts
AC Voltage Drop with
Inductive Load
2. Open Stator.
3. Shorted Rotor Diode.
4. Shorted Rotor Thermister.
5. Shorted Rotor Capacitor.
6. Open Rotor Diode.
1. Faulty Capacitor.
2. Open Exciter Winding.
3. Shorted Exciter Winding ..
1. Faulty Rotor Diode.
2. Faulty Rotor Winding.
3. Faulty Exciter Capacitor.
1. Faulty Rotor Diode.
2. Faulty Exciter Capacitor.
3. Amperage Overload.
NOTE:
It would be important to inspect the pulley and drive
belt under the generator base frame.
RED ISOLATION POST
WHITE
N
120V/60Hz
. BLACK
AC
·CIRCUIT
BREAKER
AC OUTPUT CONNECTIONS DIAGRAM
RED IS.Q!J\TION POST
230V/50Hz
Engines & Generators
41