PREPARATIONS FOR INITIAL START-UP
PRESTART INSPECTION
Before starting your generator set for the first time or after a
prolonged layoff, check the following items:
• Check the engine oil level. Add oil to
maintain
the level at
the high mark on the dipstick.
• Check the fuel supply and examine the fuel filter/separator
bowls for contaminants.
• Check the DC electrical system. Inspect
wire
connections
and battery cable connections.
• Check the coolant level in both the plastic recovery
tank
and at the manifold.
NOTE: After the initial running of the generator, the air in
the engine's cooling system should be purged through the
plastic coolant recovery tank. Allow the engine to cool
and then carefully remove the pressure cap on the
radiator. Ensure that the radiator is completely full of
antifreeze.
If
not, add mixture as needed to fill the
radiator. Replace the pressure cap and then add antifreeze
mixture to the plastic coolant recovery tank to fill it to half
way between "add" and "max".
• Visually examine the unit. Look for loose or missing
parts, disconnected wires, unattached hoses, and check
threaded connections. Search for any leaks.
• Check loiui leads for correct connection as specified in the
wiring diagrams.
• Examine
air
inlet and outlet for
air
flow obstructions.
• Be sure no other generator or utility power is connected to
load lines.
• Be sure that in power systems with a neutral line that
the neutral is properly grounded (or ungrounded) as the
system requires, and that the generator neutral is properly
connected to the load neutral. In single phase systems an
incomplete or open neutral can supply the wrong line-to-
neutral voltage on unbalanced loads.
A
CAUTION:
When starting the generator, it is
recommended that all AC loads, especially large
motors, be switched OFF until the engine has come
up to speed and, in cold climates, starts to warm up.
This precaution will prevent damage caused by
unanticipated operation of the AC machinery and will
prevent
a
cold engine from stalling.