SPECIFICATIONS 12.5KW BTOB
AC GENERATOR (Single Phase)
AC GENERATOR (3 Phase)
Single Phase
Voltage
Voltage Regulation
Frequency Regulation
Rating (Volis AC)
60 Hz (1800
rpm)
12.5KW
50 Hz (1500 rpm)
9.3KW
Generator Cooling
Air requirements
(60 Hz) at 1800 rpm
Generator Compartment
Ambient Temperature
Recommendations
Brushless, four pole, revolving field.
Pre-lubricated, single bearing design.
Reconnectable, single phase transformer
regulation (optional solid slate voltage
regulator)
120 or 1201240 volts - 60 hertz
230 Volls'- 50 Hertz
±S% no load to full load.
.3
Hertz (.5%)
no load to full load.
120 volts
104 amps
120/240 volts
104/52 amps
230 volls
60 amps
225 - 250 cfm (6.37 - 7.08 cmm)
NOTE:
Increase air supply 15% for 50 Hertz
operation (1500 rpm)
104°F (40
o
G) maximum
NOTE:
Forced ventilation should be provided
to maintain generator compartment
temperatures below 104°F (40°C).
Three Phase
12.5KW - SO Hertz
9.3KW· 50 Hertz
Voltage - 3 phase
(60 Hertz)
Voltage -
:3
Phase
(50 Hertz)
Amperage - 3 phase
(60 Hertz)
Amperage· 3 phase
(50 Hertz)
Generator Combustion
Air Requirements
(SO Hertz) at 1800 rpm
Generator Compartment
Ambient Temperature
Recommendations
Brushless, Six-pole, revolving field. Sealed
lubricated, single-bearing deSign. 12 Lead
reconnectable for low voltage WYE, high
voltage Delta. Solid state voltage regulator with
protection circu
ilry
Low Voltage WYE
High Voltage WYE
DELTA
High Voltage WYE
DELTA
Low Voltage WYE
High Voltage WYE
DELTA
High Voltage WYE
DELTA
41 cfm (1.16 cmm)
104°F (40oG) maximum
208 Volts
480 Volts
240 Volis
380Volis
230 Volts
43 Amps
18 Amps
37 Amps
17Amps
30 Amps
NOTE:
Forced ventilation should be provided
to maintain generator compartment
temperatures below 104°F (40°C).
SPECIFICATIONS 15KW BTOC
!
AC GENERATOR (Single Phase)
AC GENERATOR (3 Phase)
Single Phase
Brushless, four-pole, revolving field.
Three Phase
Brushless, six-pole, revolving field. Sealed
Pre-lubricated, single-bearing design.
15,0 KW· 60 Hertz
lubricated, single-bearing design. 12 Lead
Reconnectable, Single-phase transfonner
12.0 KW· 50 Hertz
reconnectable for low voltage WYE, high
regulation (optional solid-state voltage
voltage Delta. Solid state voltage regulator with
regulation).
protection circuitry
Voltage
120 or 120/240 Volts - 60 Hertz
Voltage - 3 phase 50 Hertz Low Voltage WYE
208 Volts
230 Volts - 50 Hertz.
High Voltage WYE
480 Volts
Voltage regulation:
±5% no load to full load.
DELTA
240 Volts
Voltage - 3 Phase 50 Hertz High Voltage WYE
380 Volts
Frequency regulation:
3 Hertz (5%) no load to full load.
DELTA
230 Volts
(Electronic Governered)
Non-Electric ±3 Hertz
Amperage·
Low Voltage WYE
52 Amps
3 phase 60 Hertz
High Voltage WYE
22 Amps
Rating (Volts AC)
60 Hertz (1800 rpm)
120 Volts 125 Amps
DELTA
45 Amps
120/240 Volts 125/62.5 Amps
Amperage
High Voltage WYE
22 Amps
50 Hertz (1500 rpm)
230 Volts SO Amps
3 phase 50 Hertz
DELTA
39 Amps
Generator Cooling
225 - 250 cfm (6.37 - 7.08 cmm)
Generator Compartment
104°F (40°C) maximum
Air Requirements
Ambient Temperature
(60 Hertz) at 1800 rpm
NOTE:
Increase air supply 15% for 50 Hertz
Recommendations
NOTE:
Forced ventilation should be provided to
operation (1500 rpm).
maintain generator compartment temperatures
Engine Combustion
41 cfm (1.1Scmm)
below 104°F (40°C).
Air Requirements
(60 Hertz), at 1800 rpm
Generator Compartment
104
OF
(40°C) maximum
Ambient Temperature
Recommendations
NOTE:
Forced ventilation should be provided to
maintain generator compartment temperatures
below 104°F (40cC).