6.0Kw . 10.0N .5Kw - Westerbeke 8.0KW - 60Hz Operator's Manual

Marine diesel generators single and three phase
Hide thumbs Also See for 8.0KW - 60Hz:
Table of Contents

Advertisement

SPECIFICATIONS 8.0KW BTDA
AC GENERATOR (Single Phase)
Single Phase
Brushless, four-pole, revolving field.
Pre-lubricated, single-bearing design .
Reconnectable, single-phase transformer
regulation (optional solid-state voltage
regulation).
Voltage
120 or 1201240 Volts - 60 Hertz
220 Volts - 50 Hertz.
Voltage regulation:
±5% no load to full load.
Frequency regulation:
.5 Hertz (.60%)
no load to full load.
Rating (Volts AC)
60
Hertz~18oo
rpm}
120 Volts
66 Amps
8.DKW
1201240 Volts
66/33 Amps
50 Hertz (1500 rpm)
220 Volts
27 Amps
6.DKW
Generator Cooling
175 - 200 clm (4.95 - 5.66 cmm)
Air Requirements
(60 Hertz) at 1800 rpm
NOTE: Increase air supply 15% for 50 Hertz
operation (1500 rpm).
Engine Combustion
42 elm (1.19 cmm)
Air Requirements
(60 Hertz). at 1800 rpm
Engine Compartment
100 - 200 cfm (2.83 - 5.66 cmm)
Cooling Air
Generator Compartment
104°F (40°C) maximum
Ambient Temperature
Recommendations
NOTE: Forced ventilation should
be provided
to maintain generator compartment
temperatures below 104°F (40·C).
SPECIFICATIONS 10.0KW BTDA
AC GENERATOR (Single Phase)
AC GENERATOR (3 Phase)
Single Phase
Brushless, four pole, revolving field.
General • 3 Phase
Brushless, Six-pole, revolving field. Sealed
Pre-lubricated, single bearing design.
10.0 Kw· 60 Hertz
lubricated, single-bearing design. 12 Lead
Reconnectable, single phase transformer
7.5 Kw - 50 Hertz
reeonnectable for low voltage WYE, high
regulation (optional solid state voltage
voltage Delta. Solid state voltage regu lator with
regulator)
protection circuitry
Vortage
120 or 1201240 volts - 60 hertz
Voltage - 3 phase
Low Voltage WYE
240 Volts
220 Volts - 50 Hertz
(60 Hertz)
High Voltage WYE
480 Volts
Vortage Regulation
± 5%
no load to full load.
DELTA
240 Volts
Frequency Regulation
.5 Hertz (.60%)
no load to full load.
Voltage - 3 Phase
High Voltage WYE
380 Volts
(50 Hertz)
DELTA
220 Volts
Rating (Volts AC)
Amperage - 3 phase
Low Voltage WYE
35 Amps
60 Hz (1800 rpm)
120 volts
83.3 amps
(60 Hertz)
High Voltage WYE
15 Amps
10.0KW
1201240 volts
83.3/41.6 amps
DELTA
30 Amps
50 Hz (1500 rpm)
220 volts
32.6 amps
Amperage - 3 phase
High Voltage WYE
14 Amps
7.SKW
(50 Hertz)
DELTA
24 Amps
Generator Cooling
225 - 250 efm (5.66 - 6.37 emm)
Engine Combustion
42 efm (1.19 cmm)
Air requirements (60 Hz) at 1800 rpm
Air Requirements
(60 Hertz), at 1800 rpm
NOTE: Increase air supply 15% for 50 Hertz operation (1500 rpm)
Engine Compartment
100 - 200 cfm (2.83· 5.66 cmm)
Engine Combustion
42 cfm (1.19 cmm)
Cooling Air
Air Requirements
Generator Compartment
104°F (40oG) maximum
,
Ambient Temperature
Generator Compartment
104°F \ 40·C) maximum
Ambient Temperature
Recommendations
NOTE: Forced ventifation slJould be provided
Recommendations
NOTE;
Forced ventilation should be provided
to
maintain generator compartment
to maintain generator compartment
temperatures be/ow 104°F (40·C)
temperatures below 104°F (40·C).
Engines & Generators
48

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents