MAINTENANCE SCHEDULE
NOTE:
Use the engine Iwur meter gauge to log your engine hours or record your
engine Iwurs
by
running time.
CHECK
HOURS OF OPERATION
SCHEDULED
EACH
EXPLANATION OF SCHEDULED
MAINTENANCE
DAY
50
100 250
500
750 1000 1250
MAINTENANCE
Raw Water Pump
0
0
0
Remove the pump cover and inspect the impeller,
gasket, cam and cover for wear. Check the bearings
and seals (the shaft can turn, but not wobble).
Lubricate both when reassembled.
Coolant System
0
0
Drain, flush, and refill cooling system with
appropriate antifreeze mix.
Electric Fuel
Lift
0
0
0
0
0
0
Periodically check the wiring connections.
Pump Filter (If applicable)
Replace in-line filter filter every 200 hours.
DC Alternator
0
0
0
Check DC charge from alternator. Check mounting
bracket; tighten electrical connections.
*Fuellnjectors
Check and adjust injection opening pressure and
spray condition (see ENGINE ADJUSTMENTS).
*Starter Motor
0
0
Check solenoid and motor for corrosion. Remove
and lubricate. Clean and lubricate the starter motor
pinion drive.
*Preheat Circuit
0
0
Check operation of preheat solenoid. Remove and
clean glow plugs; check resistance (4-6 ohms).
Reinstall with anti seize compound on threads.
*Englne Cylinder
0
0
Check compression pressure and timing (see Engine
Compression
Adjustments).
*Torque Cylinder Head
0
0
0
At first 50 hours, then every 500 hours (see
Hold-down bolts
ENGINE ADJUSTMENTS).
*Adjust the Valve Clearances
0
0
0
Adjust Valve Clearances (see ENGINE
ADJUSTMENTS).
"Heat Exchanger
0
Remove, have professionally cleaned and pressure
tested.
Air Intake Filter
0
0
0
0
0
Clean every 100 operating hours. Replace as
needed. Refer to page 17 of this manual.
"WESTERBEKE recommends this service be performed by an authorized mechanic.