Westerbeke 10TWO Operator's Manual page 36

Marine engine and generator set
Hide thumbs Also See for 10TWO:
Table of Contents

Advertisement

SOUND GUARD INSTRUCTIONS
INSTRUCTIONS
1. Plywood b3se, generator set bolls and skirt are in place as re-
ceived.
2. Hoist the generator set enough so that two men can lift the
plywood base and enter the bolts into corresponding holes il
generator set rails. Spin nuts finger tight. Assembly may then b,
lowered into position and bolting completed
3. The generator set and base may then be bolted to the sub-bas'
through holes in corner of the plywood.
4. To assemble frame, follow the drawing. Be sure that open holes
are opposite guide pins and that riveted screw receptacles are
opposite screws.
5. On units which require a fan foUow this procedure:
A. Remove 4 short screws which hold fresh water pump pulley
hub.
8. Reassemble hub with fan, fan spacer, and 4 cap screws fur-
nished. Tighten securely.
6. Holes for fuel lines, battery cables, remote panel cable, and power
lines are to be cut in the lower skirt by the installer. These holes
should be Gut to minimum usable size in order to minimize the
escape of sound.
Make
a
final check to be sure fan has clearance in its opening, that
the fresh air duct from intake plenum to engine air intake is
clamped in place, and that there is a tight fit of air plenum against
the end of the generator to prevent re-circulation of air.
8. If you plan to order SOUND GUARD, order the generator set with
remole panel and cable extension.
CAUTION: With the air discharge end panel removed, the fan is
exposed and unprotected.
00 NOT remove air discharge end panel without firs! stopping engine
SIMPLE QUICK ACTION LOCK AND
EASY TO ASSEMBLE
COA~JER
DETAil
BA TTEAY CONNECTIONS
WATER INJECTED RUBBER EXHAUST
HOSE TO WATER LIFT TYPE MUFFlER
FLEX DUCT FOR COMBUSTION AIR
WARNING
Air in generator compartment should not
exceed 100 degrees F. If higher tempera-
tures are expected, an exhaust blower
should be installed.
34
SOUND GUARD AIR FLOW DIAGRAM
9. The engine must receive combustion air from outside the
SOUND GUARD. Be sure that flex duct for combustion air
is
10.
set up tl18
Do
not use excessive
DISCHARGE FAN
NOTE:
FM~
ASSEMBLY IS REQUIRED
ON CERTAIN MODELS
'INTAKE FOR SEA WATER

Advertisement

Table of Contents
loading

This manual is also suitable for:

3kw

Table of Contents