Generator
Voltage
Load
Speed
l15v.
230v.
AEElied
4 Eole
Freguency
Plants
Plants
None
1830
61
129
258
Half
1800
60
120
240
Full
1755
58~
115
230
The output voltage should be checked periodically to insure proper
operation of the generating plant and appliances.
If the genera-
tor
is not equipped wi th a vol tmeter,
it can be checked wi th a
portable meter.
3.
Maintenance
See the engine instruction book for engine maintenanceo
BRUSHES -
Check the brushes
for
ylear
after
about 1000 hours of
operation and
every few
hundred
hours
of operation
thereafter.
They should be replaced when worn down to one half inch.
Whenever
replacing
brushes
or
removing
them
to
do
other
service
work,
remove one brush at a time and put the screws back into the brush
holder
to hold the wire terminals on place so there will be no
difficulty replacing the wires correctly.
COlviMUTATOR -
A commutator
and is brownish in color.
may
be
cleaned
with
very
cloth. )
in good condi tion has a glossy finish
If it gets greasy, rough or dirty, it
fine
sandpaper.
(Do
not
use
emery
BEARINGS - All ball bearings used in these generators are packed
with grease before assembly - no further greasing is
required~
If
they become rough or worn, they should be replaced.