Westerbeke BCG4.0KW Operator's Manual page 64

Marine gasoline generators sets
Table of Contents

Advertisement

"' "
w
-'
N
...
~
~
::
'"
e
'"
"'
THE 17 PLUG IS
SHOWN CONNECTED
TO THE CAPACITOR
ONLY FOR DEMON-
STRATION PURPOSES.
BCG 6.SKW GENERATOR
58 Hertz
Plug
A. Check the resistance of the exciter windings
BCG 6.5KW : 1.9 Ohms
C. Check the engine's speed.
60 Hertz: 60.5 - 61.5
50 Hertz: 50.5 - 51.5
AC Load Connection
Ter.inal Block
Capacitor
Adjustment
Plugs
CAUTION:
DO
NOT
ALLOW
THESE
PLUGS
TO
TOUCH
THE
GEHERATOR"S
HOUSING.
WINDINS
WILL BURN
IF
PLUGS
TOUCH
HOUSING
OR
OTHER WIRES.
B. Check the capacitor.
BCG 6.5KW: 31.5 uF ± 5"
Adjust the engine's speed by use of the governor speed adjustment, page 74, to obtain the correct Hertz.
NOTE: Refer to the "NOTE" at the bottom of page 62.