Westerbeke BCG4.0KW Operator's Manual page 16

Marine gasoline generators sets
Table of Contents

Advertisement

BeG
4.0KW SYSTEM SPECIFICATIONS
AC GENERATOR
General
Voltage
Rating (Volts AC)
60 Hertz (1800 rpm)
50 Hertz (1500 rpm)
AC Circuit Breaker
Generator Cooling
Air Requirements, (60 Hertz),
at 1800 rpm
Brushless, four-pole, revolving field.
Self exciting. Capacitor saturated field excitation.
Pre-lubricated, single-bearing design.
Reconnectable 120 Volls or 120[240 Volts,
single-phase
120 or 120[240 Volts - 60 Hertz
220 Volts - 50 Hertz.
Voltage regulation: ±5% no load to
full load.
Frequency regulation: ± 3 Hertz (5%)
no-load to fUll-load.
120 Volts
120[240 Volts
220 Volts
34 Amps
34[17 Amps
14 Amps
To be rated at 120% of the generator's rated
amperage and voltage output.
225 elm (6.4 cmm)
NOTE: Increase air supply 15% for 50 Hertz operation (1500 rpm).
Engine Combustion Air
Requirements, (60 Hertz),
at 1800 rpm
TUNE-UP SPECIFICATIONS
Spark Plug Gap
Contact Point Clearance
Timing
18 cfm (0.509 cmm)
0.028 - 0.036 inches (0.70 - 0.90 mm)
0.016 - 0.020 inches (0.4 - 0.5 mm)
16' ± l' BTDC at 1800 rpm
13
Westerbeke Generators

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcg6.5kw

Table of Contents