OPERATING INSTRUCTIONS

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Turn
the Power Switch of the tool to its "OFF" position and unplug the tool
from its electrical outlet before performing any inspection, maintenance,
RIGHT RAIL
STAND (41)
T-KNOB (42)

Tool Set Up

To Fill And Drain The Water Tray:
WATER TRAY (67)
1.
Fill Water Tray (67) with enough clean, cold
water to submerge 3/4 of the Water Pump.
Do not overflow the Tray. (See Figure 9.)
NOTE: To prevent excessive wear on
the Saw Blade, make sure to maintain a
continuous flow of water over the entire Saw
Blade while cutting. Never cut anything
if the water flow is not continuous.
2.
Prior to draining the Water Tray (67) first
place a large bucket under the Drain Plug
(69). Remove the Drain Plug (69) located at
the bottom of the Water Tray. Once drained,
replace the Drain Plug. NOTE: You may also
pull out the Water Tray from the Tile Saw
and pour out the water. (See Figure 9.)
3.
After draining the water, rinse
Tray to remove any silt.
To Make A Straight Cut:
WARNING! Use safety equipment. Always
wear eye protection. Wear ANSI approved
safety glasses under an ANSI approved
full face safety shield and non-skid safety
shoes. Hearing and breathing protection
must be used for appropriate conditions.

DRAIN PLUG (69)

FIGURE 9