Using Raid 5 Mode (3 Hard Drives) - Buffalo TeraStation User Manual

Network attached storage
Hide thumbs Also See for TeraStation:
Table of Contents

Advertisement

Using RAID 5 mode (3 hard drives)

1
Change system to normal mode (page 20).
2
3
4
5
Note:
After the RAID array is changed, the TeraStation will perfom a RAID check that will take about 5 hours per TB. File
transfers will be slower during this period. While the "RAID ARRAY x Resyncing" message is displayed on the LCD
screen, do not turn off the TeraStation. If you turn it off, the RAID check will start over.
6
The [Confirm Operation] screen will appear. Enter the number shown in the [Confirmation Number] field within
60 seconds, and click [Apply].
7
Follow the instructions displayed on the screen.
You have now set up a RAID 5 array. Refer to page 26 to configure a hot spare with the remaining drive. Turn to page
43 to create a shared folder.
TeraStation User Manual
Click [System] - [Storage] - [RAID Array] in the Web Admin interface.
Click the array you want to configure.
Select hard disks (3 of them) to use in RAID5.
1
Select [RAID5].
2
Click [Create Raid Array].
22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents