PORT <port>|ALL TELSERVER ENABLE|DISABLE
[LOCALIPPORT=<lport>]
[TIMEOUT=<sec>] [BUFFERING=<hsec>]

Port TCP Server command

The Port TCP Server command enables or disables the raw TCP server connection
method on a serial port. See Table 9 on page 11 for parameter descriptions and rules
for use.
PORT <port>|ALL TCPSERVER ENABLE|DISABLE
[LOCALIPPORT=<lport>] [TIMEOUT=<sec>]
[BUFFERING=<hsec>] [IDLEBUFFERING ENABLE|DISABLE]

Port TCP Client command

The Port TCP Client command enables or disables the raw TCP client connection
method on a serial port. See Table 10 on page 12 for parameter descriptions and rules
for use.
PORT <port>|ALL TCPCLIENT ENABLE|DISABLE
DESTIP=<dest_ip> [DESTPORT=<dest_port>] [LOCALPORT=<lport>]
[CONNECTMODE=AUTO|DATA] [TIMEOUT=<sec>]
[BUFFERING=<hsec>] [IDLEBUFFERING ENABLE|DISABLE]

Port Configuration Utility command

The Port Configuration Utility command enables or disables the configuration utility
connection method on a serial port. See Table 11 on page 13 for parameter
descriptions and rules for use.
PORT <port>|ALL CONFIGUTIL ENABLE|DISABLE [TIMEOUT=<sec>]

6.4 Port Attributes Command

The Port Attributes command specifies a serial port's attributes. See Table 12 on
page 14 for serial port parameter descriptions and rules for use.
PORT <port>|ALL [BAUD=<baud>] [SIZE=<size>]
[PARITY=NONE|EVEN|ODD|MARK|SPACE] [STOP=1|2]
[FLOW=NONE|XON/XOFF]

6.5 Network Command

The Network command specifies the ESP-2 hub address information.
NETWORK IP=<ip> MASK=<mask> GATEWAY=<gateway>
The addresses must be entered in standard IP dot notation. The gateway address must
be in the same subnet as the IP address. You cannot set the IP address to: a Class A
address of 0.0.x.x, a loopback address of 127.x.x.x, the default value of 192.1.1.1 or
an address at or above 248.x.x.x. The subnet mask cannot be 0.0.0.0.