Serial Port Attributes - Equinox Systems ESP-2 OPTO Installation And User Manual

Serial hub
Hide thumbs Also See for ESP-2 OPTO:
Table of Contents

Advertisement

Table 11: Configuration Utility Connection Method Configurable Items (Continued)
Item
Description
Specifies the length of time before the configuration utility is disconnected if
there is no activity. Valid values are 0-65535 seconds.
Inactivity time-
For example, a value of 60 indicates the configuration utility will be
out
disconnected if there is no activity for a period of 60 seconds.
A 0 value disables the inactivity time-out. The default value is 0 (disabled).

3.6 Serial Port Attributes

Each serial port has a set of attributes, which may be modified.
NOTE: When a port is configured for the serial redirection connection method, the attributes are
specified within the protocol. Therefore, although you may change the attributes, any changes
you specify will not take effect.
Table 12 lists the serial port attributes with their valid and default values.
Table 12: Serial Port Valid and Default Values
Attribute
Baud rate
Bits per character
(size)
Parity
Stop bits
Flow control
14
Valid and Default Values
Valid values: 50, 75, 110, 134, 150, 200, 300, 600, 1200, 2400, 4800,
9600, 19200, 38400, 57600, 76800, 115200 and 230400
Default value: 19200
Valid values: 5, 6, 7 and 8
Default value: 8
Valid values: None, Even, Odd, Mark and Space
Default value: None
Valid values: 1 and 2
Default value: 1
Valid values: None and XON/XOFF
Default value: None
Flow control settings are full duplex
Equinox ESP-2 OPTO Serial Hub Installation and User Guide