B: Switch Test; C: Temperature Fuse Test; D: Motor Winding Test; E: Fuse F10A - Sharp R-350Y Service Manual

Microwave oven
Table of Contents

Advertisement

CAUTION: 1 C CORRESPONDS TO 120 WATTS. REPEAT MEASUREMENT IF THE POWER IS INSUFFICIENT.
1000g
T1 C

[2] B: SWITCH TEST

CARRY OUT 3D CHECKS.
Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the following table.
Table: Terminal Connection of Switch
Plunger Operation
COM to NO
Released
Open circuit
Depressed
Short circuit
If incorrect readings are obtained, make the necessary switch adjustment or replace the switch.
CARRY OUT 4R CHECKS.

[3] C: TEMPERATURE FUSE TEST

CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the temperature fuse. Then using an ohmmeter, make a continuity test across the two terminals as
described in the below.
Parts Name
Temperature fuse 150 C
If incorrect readings are obtained, replace the temperature fuse.
An open circuit temperature fuse (OVEN) indicates that the foods in the oven may catch fire, this may be due to over heating produced by improper
setting of the cooking time or failure of the control panel.
CARRY OUT 4R CHECKS.

[4] D: MOTOR WINDING TEST

CARRY OUT 3D CHECKS.
Disconnect the leads from the motor. Using an ohmmeter, check the resistance between the two terminals as described in the table below.
Motors
RMOTEA450WRZZ
Resistance
Approximately 384
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS.

[5] E: FUSE F10A

CARRY OUT 3D CHECKS.
1. If the fuse F10A is blown, there could be shorts or ground in electrical parts or wire harness.Check them and replace the defective parts or repair
the wire harness.
2. If the fuse F10A is blown when the door is opened, check the 1st. latch switch, 2nd. interlock relay and monitor switch.
If the fuse F10A is blown by incorrect door switching replace the defective switch(s) and the fuse F10A.
CARRY OUT 4R CHECKS.
CAUTION: ONLY REPLACE FUSE F10A WITH THE CORRECT VALUE REPLACEMENT.
1000g
Heat up for 38 sec.
COM to NC
COM; Common terminal
Short circuit
NO; Normally open terminal
Open circuit
NC; Normally close terminal
Table: Temperature Fuse Test
Temperature of "ON" condition
(closed circuit).
This is not resetable type.
Table: Resistance of Motor
F
a
n
m
t o
r o
RMOTEA475WRZZ
Approximately 333
Temperature of "OFF" condition
(open circuit).
Above 150
C
RMOTDA253WRZZ
RMOTDA289WRZZ
Approximately 14.5k
Approximately 13.5k
8 – 2
1000g
T2 C
Indication of ohmmeter (When room
temperature is approx. 20 C.)
C
o l
s
e
d
i c
T
u
n r
a t
b
e l
m
t o
r o
RMOTDA302WRE0
Approximately 14.7k
R-350Y(S)
c r
u
t i

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-350ysR-350yw

Table of Contents