AXIS Q8108-R User's Guide
Pin assignment - I/O connector
Pin
Function
number
1
Output 1
2
Output 2
3
Input 1
4
Input 2
5
Input 3
6
Input 4
7
Input 5
8
Input 6
9
Input 7
10
Input 8
11
5V DC
Power
12
GND

LED indicators

LED
Color
Network
Amber
Green
Unlit
Power
Green
Green and
Amber
Unlit
PoE/Link
Green
Amber
Notes
Open collector NPN transistor with the emitter
connected to ground when activated.
Outputs are reserved for developer use.
Inactive for voltages less than 1V
Active for voltages more than 3V
Only one input can be programmed via AXIS NVR
manager, see Power Configuration, on page 13
Can be used to power auxiliary equipment.
Note:
This pin can only be used as power out.
Ground
Indication
Link established.
Steady for connection to 100 Mbit/s network
For connection to 1Gbit/s network
Power supplied - normal operation.
Battery powered
Power off
Steady
Flash slowly
2 flash sequence
5 flash sequence
6 flash sequence
Link established
Specifications
Max load = 500mA
Max input = + 30V
Max load = 250mA
Power is being supplied to the camera
Short circuit
Error in PoE connection.
Connected units exceed the max load.
Connected units in the left or right group
exceed the max load.