Electronic Ignition System - KitchenAid 30" (76.2 CM) GAS DOWNDRAFT COOKTOP Installation Instructions Manual

30" (76.2 cm) gas downdraft cooktop
Hide thumbs Also See for 30" (76.2 CM) GAS DOWNDRAFT COOKTOP:
Table of Contents

Advertisement

Available languages

Available languages

Typical flexible connection.
A
B
A. Manifold entrance
B. Gas pressure regulator
C
C. Use pipe-joint compound.
D
D. Adapter (must have ½" male pipe thread)
E. Flexible connector
F. Adapter
G. Use pipe-joint compound.
E
H. Manual gas shutoff valve
I. ½" or ¾" gas pipe
F
G
H
I
4. Install the pressure regulator with the arrow pointing up
toward the bottom of the cooktop base and in a position
where you can reach the regulator access cap.
A
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Up arrow. Regulator must be installed with
arrow pointing up to cooktop bottom.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause
a gas leak. Do not allow the regulator to turn on the pipe
when tightening fittings.
Use only pipe-joint compound made for use with Natural and LP
gas.
®
Do not use TEFLON
tape. You will need to determine the fittings
required depending on your installation.
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
B
C
D
B
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
3. Remove surface burner caps and grates from parts package.
Align notches in burner caps with pins in burner base. Burner
caps should be level when properly positioned. If burner caps
are not properly positioned, surface burners will not light.
Place burner grates over burners and caps.
A
B
C
A. Burner cap
B. Burner ports
C. Burner base
D. Gas tube opening
E. Igniter head
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
4. Plug into a grounded 3 prong outlet.

Electronic Ignition System

Initial lighting and gas flame adjustments
This cooktop is equipped for electronic auto-reignition by means
of a spark igniter located at the rear of each burner. The burners
are designed to light at any valve rotation that admits sufficient
gas flow to support a flame and to automatically relight following
a loss of flame due to a draft or other adverse condition. This
feature is provided only as a convenience.
Check Operation of Surface Burners
Push in and turn the surface burners control knobs to light.
The surface burner flame should light within 4 seconds. The first
time a surface burner is lit, it may take longer that 4 seconds to
light because of air in the gas line.
Check the flame on "HIGH" for a blue color. It should be clean
and soft in character. No yellow tip, blowing or lifting of flame
should occur. Occasional orange flashes are normal and reflect
different elements in the air or gas.
D
E
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents