KitchenAid KECD806RBL - Pure 30 Inch Smoothtop Electric Cooktop Installation Instructions Manual

KitchenAid KECD806RBL - Pure 30 Inch Smoothtop Electric Cooktop Installation Instructions Manual

30" (76.2 cm) and 36" (91.4 cm) electric built-in ceramic downdraft cooktop
Hide thumbs Also See for KECD806RBL - Pure 30 Inch Smoothtop Electric Cooktop:
Table of Contents

Advertisement

Available languages

Available languages

30" ( 76.2 cm) and 36" (91.4 cm) ELECTRIC
Built-in Ceramic Downdraft Cooktop
IMPORTANT:
Read and save these
instructions.
IMPORTANT:
Installer: Leave Installation
Instructions with the homeowner.
Homeowner: Keep Installation
Instructions for future reference.
Save Installation Instructions for local
electrical inspector's use.

Installation Instructions

Write down the model and serial numbers
before installing cooktop.
Both numbers are on the model/serial
rating plate, located on the bottom of the
cooktop.
Model #___________________________
Serial # ___________________________
Part No. 8286553

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KECD806RBL - Pure 30 Inch Smoothtop Electric Cooktop and is the answer not in the manual?

Questions and answers

Summary of Contents for KitchenAid KECD806RBL - Pure 30 Inch Smoothtop Electric Cooktop

  • Page 1: Installation Instructions

    Installation Instructions 30" ( 76.2 cm) and 36" (91.4 cm) ELECTRIC Built-in Ceramic Downdraft Cooktop IMPORTANT: Read and save these instructions. Write down the model and serial numbers before installing cooktop. IMPORTANT: Both numbers are on the model/serial Installer: Leave Installation rating plate, located on the bottom of the Instructions with the homeowner.
  • Page 2: Tools And Materials Needed For Installation

    Before you start... Important: Observe all governing Your safety and the safety of WARNING: To reduce the risk of fire, codes and ordinances. Failure to meet others is very important. electric shock, or injury to persons, codes and ordinances could lead to observe the following: We have provided many important fire or electrical shock.
  • Page 3: Product Dimensions

    Product Dimensions Cutout Dimensions 29-1/2" (74.9 cm) - 30" (76.2 cm) model 30-3/8" (77.1 cm) - 30" (76.2 cm) models 35-1/2" (90.2 cm) - 36" (91.4 cm) model 21-5/16" 36-3/8" (92.3 cm) - 36" (91.4 cm) models cutout width (54.1 cm) width depth 21"...
  • Page 4: Venting Methods

    Venting system requirements The blower housing is set to vent Venting system must terminate to the Do Not exhaust more than one straight out the back from the cooktop. To outside. downdraft cooktop into a single vent vent down, left or right, see “Installation,” system.
  • Page 5 Determine equivalent length of vent. Maximum 6" (15.2 cm) round metal vent equivalent length of vent is 60 ft (18.3 m). 6" (15.2 cm) transition wall round PVC List the number of each piece and length of straight vent you will use. 6"...
  • Page 6: Electrical Requirements

    supply is required on a separate Electrical The recommended minimum copper 30-ampere circuit, fused on both sides wire size is No.-10 gauge. However, requirements of the line. wire sizes and connections must conform A time-delay fuse or circuit breaker is to the requirements of the National recommended.
  • Page 7 For all cooktop models with three-wire cable from the cooktop: Where local codes Do Not permit connecting the frame- Where local codes permit connecting the frame-ground ground conductor to the neutral (white) junction box conductor to the neutral (white) junction box wire. (Not wire.
  • Page 8: Cooktop Removal

    5. Separate the factory-crimped bare and Check operation For all cooktop models with four- white cooktop cable wires. wire cable from the cooktop. 6. Connect the two white wires together (These cooktops are using twist-on connectors. Turn on electrical supply. manufactured with white 7.
  • Page 9 NOTES...
  • Page 10 NOTES...
  • Page 11: Instructions D'installation

    Instructions d’installation Table de cuisson encastrée électrique en céramique de 76,2 cm (30 po) et 91,4 cm (36 po) à aspiration vers le bas IMPORTANT : Lire et conserver ces instructions. Inscrire ci-dessous les numéros de modèle et de série, avant d'installer la IMPORTANT : table de cuisson.
  • Page 12: Pièces Fournies

    Avant de commencer... électriques ANSI/NFPA 70 - dernière nécessaire, il est possible de réduire le Votre sécurité et celle des autres édition*, ou des normes CSA C22.1.94, risque en installant sous les placards est très importante. du Code canadien des installations une hotte de cuisinière qui fait saillie électriques (partie 1) et C22.2 N 0-M91 Nous donnons de nombreux...
  • Page 13: Dimensions Du Produit

    Dimensions du produit Dimensions de l’ouverture à découper largeur de 77,1 cm (30 3/8 po) - table de cuisson de 76,2 cm (30 po) 74,9 cm (29 1/2 po) - table de cuisson de 76,2 cm (30 po) largeur de 92,3 cm (36 3/8 po) - table de profondeur 90,2 cm (35 1/2 po) - table de cuisson de 91,4 cm (36 po) cuisson de 91,4 cm (36 po)
  • Page 14 Prescriptions concernant le système d’évacuation Le système doit décharger l’air à bas, vers la gauche ou vers la droite, voir La longueur du conduit et le nombre l’extérieur. “Installation”, Étape 2, page 6. de coudes devraient être maintenus au minimum pour une performance Ne pas terminer le conduit d’évacuation La longueur nominale d’un conduit efficace.
  • Page 15 conduit métallique diam. 15,2 cm (6 po) raccord de Déterminer la longueur équivalente du conduit transition tuyau PVC/ d’évacuation. La longueur équivalente maximale du bouche de égout diam. conduit métallique décharge conduit d’évacuation est de 18,3 m (60 pi). 15,2 cm (6 po) diam.
  • Page 16: Spécifications Électriques

    On recommande l’emploi d’un fusible On doit installer un connecteur vissable Spécifications ou d’un disjoncteur sur les deux de conduit de 12,7 mm (1/2 po) conducteurs. La capacité du fusible ne (homologation U.L.) à la boîte de électriques doit pas dépasser la demande de connexion.
  • Page 17: Raccordement Électrique

    Raccordement Pour toute table de cuisson alimentée par un câble à 3 conducteurs. électrique Lorsque le code local NE PERMET PAS le raccordement du conducteur blanc (neutre) du câble d’alimentation au conducteur de liaison à la terre (utilisation dans une installation au Canada) : AVERTISSEMENT Câble d’alimentation à...
  • Page 18 Pour une table de cuisson Pour toute table de cuisson alimentée par un câble à 4 conducteurs avec câble d’alimentation à (le conducteur blanc (neutre) du câble d’alimentation est raccordé à 4 conducteurs (le câblage de un conducteur nu de liaison à la terre, connecté à la caisse). ces tables de cuisson comporte un conducteur Lorsque le code local NE PERMET PAS le raccordement du conducteur blanc...
  • Page 19: Si La Table De Cuisson Ne Fonctionne Pas

    Vous avez terminé l’installation de Vérifier le fonctionnement votre nouvelle table de cuisson à Vérifier que le système aspiration vers le bas. Pour d’aspiration vers le bas fonctionne. Si la obtenir l’utilisation la plus table de cuisson ne fonctionne pas, Rétablir le courant électrique.
  • Page 20 NOTES...

Table of Contents