Chapter 6:
Graphics Engine Overview
DL.3, DL.2, and Axon Media servers all use the same graphic engine
software to control content selection, playback, and 3-D Object and Global
manipulation.
Protocol Options
DL.3, DL.2 and Axon models all provide individual and composite graphical control for up to
three 3-D Objects. You can control the "footprint" of the fixture on a DMX link by choosing to
implement only the number of 3-D objects you need. Select the protocol level in the fixture's
onboard menu system for DL.3 and DL.2 fixtures or through the CMA for both fixture and Axon
media servers (see Viewing Server Configuration on page 182).
Appendix A: DMX Protocol on page 195 has a detailed listing of all the parameters for Axon
media servers and they are discussed in more detail in the following chapters.
Standard Protocol
Dual Protocol
Single Protocol
Image Optimizing Controls
Images can now be optimized for each cue. It is no longer necessary to pre-optimize images
with a separate software system on a separate computer when preparing for a show. Using
Visual modes, (see Visual Mode Options on page 62), you can adjust both Black Level and
Contrast for each cue and for each image.
Axon Media Server User Manual
Protocol Selection
DMX Channel Range
Axon
DL.3 and DL.2
149
170
111
132
73
94
35