Superior BBV-36RMN Installation Instructions Manual page 8

Standard series 36" b-vented gas appliances
Table of Contents

Advertisement

Note: Supply wires may be alternatively connected to the outlet using the screw terminals,
however the black supply wire must be wired to a terminal that is opposite (across the outlet) the
point where the white supply wire is connected.
Ground Wire
Connection
White
(Supply)
120 Vac
60 Hz
Black
(Supply)
Figure 15
Gas Flex Line (provided)
" x
" Flare
Shut-Off Valve
(may be required in some areas, consult local codes.)
Gas Stub
Note:
" NPT At Inlet Of Gas Valve For Electronic Models.
Figure 16
8
" Flex Tubing
Alternate "Hard Piping"
" Close Nipple
" Shut-Off Valve
" x
" Reducer
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Bipolar
Terminal
Screw
Gas Valve
(Millivolt or
Electronic)
" NPT Flare Fitting
(Remove Before
Hard Piping)
" Nipple
" Union
WARNING: DO NOT REMOVE THE AC-
TUATOR ARM LOCKING SCREW UNLESS
THE COMPLETE OUTSIDE AIR VENT SYS-
TEM HAS BEEN INSTALLED IN ACCOR-
DANCE WITH THE DETAILED INSTRUC-
TIONS PROVIDED WITH THE KIT.
Locate the actuator arm along the right side of
the appliance firebox opening and refer to Fig-
ure 17 . After completing the installation of the
Outside Combustion Air Kit remove and discard
the actuator arm locking screw.
Combustion Air
Actuator
Remove Locking Screw
and "Pop" Actuator to the
Left Before Initial Use
Pull Forward to Open,
Push Back to Close
Figure 17
To operate, push the end of the actuator to the
left as shown in Figure 17 , until it "pops" free
of its "locked" position. Pull the actuator for-
ward to open the combustion air door, and
push it back to close. To "lock" the combustion
air door closed, ensure the actuator is pushed
all the way back then push the end of the
actuators to the right until the step in the
actuator moves behind the appliance front
face within the slotted opening.
Operate the actuator through several cycles
including the "lock" position. Ensuring proper
operation and freedom of movement. Return
the actuator arm to the locked position.
Step 8. Installing Logs and Rockwool – The
logs are packaged and boxed within the firebox.
The bag of rockwool is in the lower control
compartment. Remove the rockwool from the
packaging and tear into quarter size pieces (see
Homeowners Care and Operation Instructions).
Spread along the front edge of the front burner.
Do not use more than is necessary.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bbv-36rmpBbv-36renBbv-36rep

Table of Contents