Cold Climate Insulation; Installation Accessories - Superior BBV-36RMN Installation Instructions Manual

Standard series 36" b-vented gas appliances
Table of Contents

Advertisement

14
14
13
12
Min. Height of
11
Mantel Above
10
Fireplace
9
Opening
8
0
Three mantels are shown (dark gray elongated rectangles) - one, 1
above the fireplace opening; the second, 8 in. long at a min. of 12 in. above the fireplace opening;
and the third, 12 in. long at a min. of 14
between these three in length, they must be located within the lighter gray shaded area.
Figure 23
0" (0 mm) Clearance
to Combustible
Side Wall
Max. Projection 12" (305 mm)
Combustible
Mantel
Figure 24
A hearth extension is not required with this
appliance. Any hearth extension used is for
appearance only and does not have to conform
to standard hearth extension installation re-
quirements.
Combustible
Mantel Clearances
Inches
12
11
10
9
8
7
6
5
4
3
2
Max.Length of Mantels
in. above the fireplace opening; for any mantels
Note: Combustible wall finish materials and/or
surround materials must not be allowed to
encroach the area defined by the appliance
front face (black sheet metal). Never allow
combustible materials to be positioned in front
of or overlapping the appliance front face.

COLD CLIMATE INSULATION

64"
(1626 mm)
Min. to
Ceiling
If you live in a cold climate, seal all cracks
around your appliance with noncombustible
14
" Min.
material and wherever cold air could enter the
(368 mm)
room. It is especially important to insulate
outside chase cavity between studs and under
floor on which appliance rests, if floor is above
ground level.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Finished
Wall
Header
Spacer
Fireplace
1
0
Opening
1
in. long at a min. of 8 in.

INSTALLATION ACCESSORIES

The following accessory items are available for
use in the installation of this appliance.
Outside Air Kits Models FOAK-4 and FOAK-4LD
Outside Air kits are available with duct
(FOAK-4) and without duct (FOAK-4LD)
for use if outside combustion air is re-
quired or desired. If model FOAK-4LD is
used it must be used in conjunction with
locally purchased, non-combustible Class
1 or Class 0 flexible duct.
Outside Combustion Air Kits
(with duct)
81L87
(without duct)
81L88
Wall Switch Kit
85L87
FOAK-4
FOAK-4LD
FWSK
11