Specifications; Troubleshooting Guide - Heath Zenith SL-5512 Owner's Manual

Twin halogen motion sensing light
Hide thumbs Also See for SL-5512:
Table of Contents

Advertisement

Available languages

Available languages

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[var ies with surrounding
temperature]
Sensing Angle . . . . . . Up to 240°
Electrical Load . . . . . . Up to 300 Watt Maximum Incan-
descent [Up to 150 Maximum
each lamp holder].
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
Replacement lamp . . . T3, 150W halogen maximum
120 VAC
D
B
Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn
®
ual
rite
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
SYMPTOM
POSSIBLE CAUSE
Lights will not come
1. Light switch is turned off.
on.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
6. Light control aimed in wrong direction.
Lights come on in day-
1. Light control may be installed in a relatively dark
light.
2. Light control is in TEST.
Lights come on for no
1. Light control may be sensing small animals or auto-
apparent reason.
2. Range is set too high.
3. D
Lights turn off too late in
Light control may be installed in a relatively dark loca-
Dusk-to-Dawn setting.
tion.
Lights stay on continu-
1. A lamp is positioned too close to the light control or
ously.
2. The light control may be picking up a heat source
3. Light control is in manual mode.
Lights flash on and off.
1. Heat or light from the lamps may be turning the light
2. Heat being reflected from other objects may be turn-
3. Light control is in the TEST mode and warming up.
Lights flash once, then
Light control is detecting its own lights.
stay off in manual
mode.
595-5575-09

TROUBLESHOOTING GUIDE

location.
mobile traffic.
B
timer is on.
®
ual
rite
pointed at nearby objects that cause heat to trigger
the light control.
like an air vent, dryer vent, or brightly painted, heat-
reflective surface.
control on and off.
ing the light control on and off.
SOLUTION
1. Turn light switch on.
2. Check flood lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
6. Re-aim light control to cover desired area.
1. The fixture is operating normally under these condi-
tions.
2. Set control switch to 1, 5, or 10 minutes.
1. Re-aim light control.
2. Reduce range.
3. The fixture is operating normally under these condi-
tions.
Relocate light control, or use 3 hr. or 6 hr. setting.
1. Reposition the flood lamp away from the light control
or nearby objects.
2. Reduce range.
3. Switch light control to AUTO.
1. Reposition the flood lamp away from the light con-
trol.
2. Reposition light control.
3. Flashing is normal under these conditions.
Reposition flood lamps to keep area below the light
control relatively dark.