Mode Switching Summary

TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
D
B
ual
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
Timer
®
rite

INSTALLATION

For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m)
above the ground. NOTE: If fixture is mounted higher than
8 ft. (2.4 m), aiming the sensor down will reduce coverage
distance.
CAUTION: Keep the sensor at least 1" (2.5 cm)
away from the lamps.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and
the fixture operate at high temperatures.
• Keep fixture at least 2" (5 cm) from combustible
materials. Do not aim at objects closer than 3 feet
(1 m).
• Use only T3, 150W (max.) tungsten halogen 120
VAC lamps.
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
Also for proper under eave operation, remove the
protective backing from the light shield and stick on as
shown below.
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so
the controls face down.
Light Shield
Opening
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.