I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Cooktops Series RN8450G RNL8450G RN8900G RNL8900G Date Purchased Serial Number Dealer Service Provider For use in GB &...
Contents List Waldorf Gas Cooktops RN[L]8450G Gas Cooktop 450 mm wide. RN[L]8900G Gas Cooktop 900 mm wide. Introduction ....................2 Specification ....................3 Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Dimensions ....................5 Installation ....................9...
Introduction We are confident that you will be delighted with your WALDORF GAS COOKTOPS, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Waldorf Gas Cooktops, there are two important things you can do.
Specifications Model Numbers Covered in this Specification RN[1]8450G [2]-[3] 2 Open Burners. RN[1]8900G [2]-[3] 4 Open Burners. NOTE: [1] - Back Options; - Standard Models. - Low Back Models. [2] - Open Burner Options; - With Flame Failure Protection. - With Pilot and Flame Failure Protection. [3] - Base Stand Options;...
Specifications Gas Supply Requirements - Non CE Only (Australia / New Zealand): Natural Gas LP Gas (Propane) Input Rate (N.H.G.C.) 28 MJ/hr 28 MJ/hr - each Open Burner (26,540 Btu/hr) (26,540 Btu/hr) 1.13 - 3.40 kPa 2.75 - 4.50 kPa Supply Pressure (4.5”...
Dimensions Bench Top Models RN[L]8450G-B RN[L]8900G-B...
Page 8
Dimensions Cabinet Base Models RN[L]8450G-CB = Rating Plate Location for this option. RN[L]8900G-CB...
Page 9
Dimensions Leg Stand Models RN[L]8450G-LS = Rating Plate Location for this option. RN[L]8900G-LS...
Page 10
Dimensions Dimensions for Refrigerated Base Models RN8450G models - not available in Refrigerated Base option. = Rating Plate Location for this option. RN[L]8900G-RB...
Waldorf Cooktops are designed to provide years of satisfactory service, and correct installation is essential to achieve the best performance, efficiency and trouble-free operation. This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National / Local codes covering gas and fire safety.
NOTE: All Models are delivered completely assembled. No further assembly is required, with exception of all Leg Stand Models (RN8450G-LS or RN8900G-LS), these will require assembly. Refer to 'Leg Stand Models Only' information below for assembly instructions. The appliance rear leg housings can be fitted with:- Adjustable feet to assist with levelling of appliance on uneven floors.
Page 13
Installation Rear Adjustable Feet, Fitting:- a. Secure rear of base tray to rear cooktop legs by screwing two adjustable feet supplied, into base of rear cooktop legs. b. Secure each adjustable foot, hand tight. Rear Rollers, Fitting:- a. Fit rear leg securing bolts up through Cooktop centre of rear leg housings to secure rear of base tray to rear cooktop legs and...
Installation Fitting Adjustable Feet / Rear Rollers to Cabinet and Refrigeration Bases. Rear Adjustable Feet, Fitting:- Raise appliance from floor by approximately 75mm using suitable lifting equipment (i.e. Palletiser / Forklift) to allow rear rollers to be Cabinet / removed. Refrigeration Base Unscrew and remove securing bolt securing...
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON. Waldorf Cooktops do not require electrical connection, as they function totally on the gas supply. It is essential that gas supply is correct for Cooktop to be installed and that adequate supply pressure and volume are available.
Installation Commissioning Before leaving a new installation; a. Check the following functions in accordance with operating instructions specified in ‘Operation’ section of this manual. Light the Open Burners. (F - Flame Failure Option). Light the Open Burners. (PF - Pilot and Flame Failure Option). ...
/ operator. Waldorf appliances have been designed to provide simplicity of operation and 100% safety protection. Improper operation is almost impossible, however bad operation practices can reduce the life of the appliance and produce a poor quality product.
Operation Open Burners NOTE: Only cooking pans from size Ø 150mm to Ø 420mm are suitable fo use on these open burners. Flame Failure Option (F-Models) Lighting the Open Burners Flame Failure Protection is incorporated for each burner by way of a thermo-electric system which will shut off gas supply to that burner in the event that burner goes out, so that un-burnt gas is not expelled.
Cleaning and Maintenance General Caution Always turn off the gas supply before cleaning. This appliance is not water proof. Do not use water jet spray to clean interior or exterior of this appliance. Clean Cooktop regularly. A clean Cooktop looks better, will last longer and will perform better. Carbonised grease on surface or between trivets will hinder transfer of heat from cooking surface to food.
Cleaning and Maintenance Weekly Cleaning NOTE: If Cooktop usage is very high, we recommend that weekly cleaning procedure is carried out on a more frequent basis. Ensure protective gloves are worn during cleaning process. DO NOT use harsh abrasive detergents, strong solvents or caustic detergents as they will damage cooktop and burners.
Page 21
Cleaning and Maintenance Stainless Steel Surfaces F - Option a. With burners removed, clean interior and exterior surfaces of Cooktop with hot water, a mild detergent Burner Base Locates onto solution and a soft scrubbing brush. Note gas control Cap Screw and over Flange knobs are a push fit onto gas control valve spindles and can be removed to clean front of control panel.
Cleaning and Maintenance Periodic Maintenance NOTE: All maintenance operations should only be carried out by a qualified service person. To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts should be checked and adjusted periodically by a qualified service person. If any small faults occur, have them attended to promptly.
Fault Finding This section provides an easy reference guide to more common problems that may occur during operation of your equipment. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
Gas Conversion and Specifications Conversion Procedure Caution Ensure that the Appliance is isolated from the gas supply before commencing servicing. NOTE: These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. ...
Gas Conversion and Specifications Gas Regulator NOTE, Pin rotated for Natural Gas NOTE: The gas regulator supplied is convertible between Natural Gas and LP Gas, but it’s outlet pressure is fixed ex-factory and is NOT to be NOTE, Pin rotated adjusted.
Replacement Parts List Replacement Parts List IMPORTANT: Only genuine authorized replacement parts should be used for servicing and repair of this appliance. Instructions supplied with parts should be followed when replacing components. further information servicing instructions, contact your nearest authorized service branch (contact details are as shown on reverse of front cover of this manual).
Page 27
Replacement Parts List Gas Regulators Gas Regulator Gas Type Description Part No. Nat. Gas 228531 ¾” BSP F/F Convertible. LPG / Propane Gas Conversion Kits Gas Type to Convert to Models Nat. Gas (G20) LPG (Propane) (G31) -F Models 232788 232787 -PF Models 232792...