Waldorf RN8450G Installation And Operation Manual

Waldorf RN8450G Installation And Operation Manual

450mm wide hobs 800 series

Advertisement

Quick Links

I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l
G a s C o o k t o p s
( 4 5 0 m m W i d e H o b s )
Series
RN8450G
RN8900G
Date Purchased
Serial Number
Dealer
Service Provider
RNL8450G
RNL8900G
For use in GB & IE
232778-8

Advertisement

Table of Contents
loading

Summary of Contents for Waldorf RN8450G

  • Page 1 I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l G a s C o o k t o p s ( 4 5 0 m m W i d e H o b s ) Series RN8450G RNL8450G RN8900G RNL8900G...
  • Page 2 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888 (fax) +61 (03) 9518 3833 Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281...
  • Page 3: Table Of Contents

    Contents List Waldorf Gas Cooktops RN[L]8450G Gas Cooktop 450mm wide. RN[L]8900G Gas Cooktop 900mm wide. Introduction ....................2 Specification ....................3 Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Dimensions ....................6 Installation ....................10 Installation Requirements...
  • Page 4: Introduction

    Introduction We are confident that you will be delighted with your WALDORF GAS COOKTOPS, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Waldorf Gas Cooktops, there are two important things you can do.
  • Page 5: Specification

    Specifications Model Numbers Covered in this Specification RN[1]8450G [2]-[3] 2 Open Burners. RN[1]8900G [2]-[3] 4 Open Burners. NOTE: [1] - Back Options; - Standard Models. - Low Back Models. [2] - Open Burner Options; - With Flame Failure Protection. - With Pilot and Flame Failure Protection. [3] - Base Stand Options;...
  • Page 6: Gas Supply Requirements

    Specifications Gas Supply Requirements - Australia Natural Gas LP Gas (Propane) Input Rate (N.H.G.C.) 28 MJ/hr 28 MJ/hr - each Open Burner 1.13 - 3.40 kPa 2.75 - 4.50 kPa Supply Pressure Burner Operating Pressure (*) 0.95 kPa 2.6 kPa See ‘Gas Connection’...
  • Page 7: Gas Connection

    Specifications - All Other Markets Natural Gas Town Gas (**) Input Rate (N.H.G.C.) 28 MJ/hr 28 MJ/hr - each Open Burner 1.13 - 3.40 kPa 0.75 - 1.50 kPa Supply Pressure 0.95 kPa 0.63 kPa Burner Operating Pressure (*) Gas Connection See ‘Gas Connection’...
  • Page 8: Dimensions

    Dimensions Bench Top Models RN[L]8450G-B RN[L]8900G-B...
  • Page 9 Dimensions Cabinet Base Models RN[L]8450G-CB = Rating Plate Location for this option. RN[L]8900G-CB...
  • Page 10 Dimensions Leg Stand Models RN[L]8450G-LS = Rating Plate Location for this option. RN[L]8900G-LS...
  • Page 11 Dimensions Dimensions for Refrigerated Base Models RN8450G models - not available in Refrigerated Base option. = Rating Plate Location for this option. RN[L]8900G-RB...
  • Page 12: Installation

    Waldorf Cooktops are designed to provide years of satisfactory service, and correct installation is essential to achieve the best performance, efficiency and trouble-free operation. This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National / Local codes covering gas and fire safety.
  • Page 13: Clearances

    NOTE:  All Models are delivered completely assembled. No further assembly is required, with exception of all Leg Stand Models (RN8450G-LS or RN8900G-LS), these will require assembly. Refer to 'Leg Stand Models Only' information below for assembly instructions.  The appliance rear leg housings can be fitted with:- Adjustable feet to assist with levelling of appliance on uneven floors.
  • Page 14 Installation Rear Adjustable Feet, Fitting:- a. Secure rear of base tray to rear cooktop legs by screwing two adjustable feet supplied, into base of rear cooktop legs. b. Secure each adjustable foot, hand tight. Rear Rollers, Fitting:- a. Fit rear leg securing bolts up through Cooktop centre of rear leg housings to secure rear of base tray to rear cooktop legs and...
  • Page 15: Fitting Adjustable Feet / Rear Rollers To Cabinet And Refrigeration Bases

    Installation Fitting Adjustable Feet / Rear Rollers to Cabinet and Refrigeration Bases. Rear Adjustable Feet, Fitting:- Raise appliance from floor by approximately 75mm using suitable lifting equipment (i.e. Palletiser / Forklift) to allow rear rollers to be Cabinet / removed. Refrigeration Base Unscrew and remove securing bolt securing...
  • Page 16: Gas Connection

    NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON. Waldorf Cooktops do not require electrical connection, as they function totally on gas supply. It is essential that gas supply is correct for Cooktop to be installed and that adequate supply pressure and volume are available.
  • Page 17: Commissioning

    Installation Commissioning Before leaving a new installation; a. Check the following functions in accordance with operating instructions specified in ‘Operation’ section of this manual.  Light the Open Burners. (F - Flame Failure Option).  Light the Open Burners. (PF - Pilot and Flame Failure Option). ...
  • Page 18: Operation

    / operator. Waldorf appliances have been designed to provide simplicity of operation and 100% safety protection. Improper operation is almost impossible, however bad operation practices can reduce the life of the appliance and produce a poor quality product.
  • Page 19: Open Burners

    Operation Open Burners ('F' - Flame Failure Option) Lighting the Open Burners Flame Failure Protection is incorporated for each burner by way of a thermo-electric system which will shut off gas supply to that burner in the event that burner goes out, so that un-burnt gas is not expelled.
  • Page 20: Cleaning And Maintenance

    Cleaning and Maintenance Before Commencing Cleaning Caution Always turn off the gas / electrical supply before cleaning the appliance. This appliance is not water proof. Do not use water jet spray to clean interior or exterior of this appliance. NOTE: ...
  • Page 21: Open Burner Cleaning

    Cleaning and Maintenance Open Burner Cleaning Stainless Steel Surfaces 1. Remove pot stands, burner caps, burner bowls 1. Clean stainless steel surfaces with hot soapy water and a soft bristled brush. and pot stand supports from top of cooktop. Wash with hot soapy water, using a soft 2.
  • Page 22: Fault Finding

    Fault Finding This section provides an easy reference guide to more common problems that may occur during operation of your equipment. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
  • Page 23: Gas Conversion And Specifications

    Gas Conversion and Specifications Conversion Procedure Caution Ensure that the Appliance is isolated from the gas supply before commencing servicing. NOTE:  These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. ...
  • Page 24: Gas Regulator

    Gas Conversion and Specifications Gas Regulator NOTE, Pin rotated - NAT Gas / LPG / Butane Only. for Natural Gas NOTE: The gas regulator supplied is convertible between Natural Gas and LP Gas, but it’s outlet NOTE, Pin rotated for LPG pressure is fixed ex-factory and is NOT to be adjusted.
  • Page 25: Gas Specifications

    Gas Conversion and Specifications Gas Specifications - Australia Natural. Gas LP Gas (Propane) Main Burner Ø 2.45mm Ø 1.50mm Open Burner Pilot Burner ('PF' Models Only) 0.30 0.20 Supply Pressure 1.13 - 3-40 kPa 2.75 - 3-40 kPa Burner Operating Pressure (*) 0.95 kPa 2.6 kPa Gas Regulator Cap Screw...
  • Page 26 Gas Conversion and Specifications - All Other Markets Natural Gas Town Gas (**) Main Burner Ø 2.45mm Ø 4.50mm Open Burner Pilot Burner ('PF' Models only) 0.30 0.60 Supply Pressure 1.13 - 3-4 kPa 0.75 - 1.5 kPa Burner Operating Pressure (*) 0.95 kPa 0.63 kPa Adjustable Regulator...
  • Page 27: Replacement Parts

    Replacement Parts List Replacement Parts List IMPORTANT: Only genuine authorized replacement parts should be used for servicing and repair of this appliance. Instructions supplied with parts should be followed when replacing components. further information servicing instructions, contact your nearest authorized service branch (contact details are as shown on reverse of front cover of this manual).
  • Page 28: Replacement Parts List

    Replacement Parts List Gas Regulators Gas Regulators Gas Type Model Part No. Description RN8400G Nat. Gas RN8600G 228531 ¾” BSP F/F Convertible. RN8800G Butane 230185 ¾” BSP F/F Adjustable. Town Gas Gas Conversion Kits Gas Type to Convert to Models Nat.

This manual is also suitable for:

Rnl8450gRn8900gRnl8900g

Table of Contents