INSTALLATION

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
For under eave installation, the sensor head must be
rotated as shown in the next two steps for proper opera-
tion and to avoid the risk of electrical shock.
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so the
controls face down.
Controls
If the sensor pops out of the ball joint, loosen the clamp
screw and push the sensor back into the ball joint.
Tighten the clamp screw when done.
These instructions show the sensor wired to floodlamps.
The white sensor wire is neutral. The black sensor
wire is hot. The red wire is the switched "hot" wire. The
lighting load (300 Watts, 2.5 A max. incandescent only)
is placed across the white and red wires.
Controls
Controls
W
t
ire
he
WARNING: Turn power off at circuit breaker or
fuse.
❒ Remove the existing light fixture, if present.
❒ After screwing the sensor into the wall plate, connect
the junction box wires to the light control wires by twist-
ing together and securing with wire connectors.
1. ALL WHITE WIRES
Junction Box
3. BLACK CONTROL
WIRE & BLACK
JUNCTION BOX WIRE
M
ount
❒ Follow the instructions that came with your light fix-
ture for mounting and adjusting the light fixture.
❒ Keep regular PAR-38 lamps at least 1" (25 mm) from
the sensor. Halogen lamps should be kept at least 2"
(51 mm) from the sensor.
2
l
C
ight
ontrol
2. RED CONTROL WIRE
& BLACK LAMP WIRES
Lamp Holders
Optional: Connect additional
load across the white and red
wires. T otal lighting load includ-
ing lampheads on fixture must
not exceed 300W (2.5A).
t
l
he
ight
598-1307-01