Installation - Heath Zenith Replacement Motion Sensor SL-5407 Owner's Manual

Replacement motion sensor
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

For under eave installation, the sensor head
must be rotated as shown in the next two steps
for proper operation and to avoid the risk of elec-
trical shock.
For eave mount only:
❒ Swing the sensor head towards the clamp
screw.
Clamp Screw
❒ Rotate the sensor head clockwise 180° so
the controls face down.
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the
ball joint. Tighten the clamp screw when done.
These instructions show the sensor wired to flood-
lamps. T he white sensor wire is neutral. T he black
sensor wire is hot. The red wire is the switched
"hot" wire. The lighting load (500 W, 4.2A max) is
placed across the white and red wires.
W
ire the
WARNING: Turn power off at the fuse or
circuit breaker.
❒ Remove the existing light fixture, if present.
Controls
Controls
L
C
ight
ontroL
❒ After screwing the sensor into the wall plate,
connect the junction box wires to the light control
wires by twisting together and securing with wire
connectors.
White to White
Junction
Box
Black to Black
Optional: Connect additional load
across the white and red wires. Total
lighting load including lampheads on
fixture must not exceed 500W (4.2A).
M
ount the
❒ Follow the instructions that came with your light
fixture for mounting and adjusting the light fix-
ture.
❒ Keep regular PAR-38 lamps at least 1" (25 mm)
from the sensor. Halogen lamps should be kept
at least 2" (51 mm) from the sensor.
-2-
Red Sensor Wire to
Black Lamp Wire
Lamp
Holders
L
ight
595-5544-06