Bleeding The Feed Tension Control - Wachs WS-8460 User Manual

Diamond wire saw
Table of Contents

Advertisement

Pivot pin
Stop collars
Figure 4-19. Make sure the pivot pin is through both
plates, then position the stop collars and tighten the
set screws.
B
F
LEEDING THE
If the feed tension control mechanism is not working prop-
erly, you will need to bleed the system. Typically, the prob-
lem will be that the system overfeeds, putting too much
tension on the wire and potentially breaking it.
For this procedure, you will need to access the tension con-
trol mechanism assembly and the spring tension assembly.
Figure 4-20 shows the location of these assemblies on the
saw.
E.H. Wachs
Set screw
T
C
EED
ENSION
ONTROL
Part No. 10-010-MAN, Rev. 1-0310
Chapter 4, Maintenance: Bleeding the Feed Tension Control
49