Do Not use an extension
cord with
this dryer.
Do Not connect
plug end of power
supply cord into a live receptacle
before
connecting
power supply cord to dryer
terminal block.
STEP 1. Turn power supply off.
STEP 2. Remove
hold-down
screw
and terminal block cover.
Hold-down
screw
Terminalblock
cover
STEP 3. Attach 3/4" U.L.-listed
strain
relief (U.L. marking on strain relief) to
the hole below terminal block opening.
Put the power supply cord through
the strain relief.
STEP 4. Remove the center terminal block
screw. Remove the neutral grounding
wire (green/yellow
wire) from external
grounding
screw.
Externalground
connector
Center silver-colored
terminal block screw
STEP 5. Connect
neutral grounding
wir_
and the neutral wire. (white) of power
supply cord under the center screw of
terminal block.
STEP El. Connect
the other two insulate(
wires to outer terminal block screws.
Us_
the same method described
in STEP 4.
STEP 7. Connect the green, grounding
wire fro'n the power supply cord to the
externar grounding
conductor
screw.
Tighten all terminal
[)lock screws firmly.
STEP 8. Tighten the strain relief screws.
STEP 9, Insert tab of terminal block
cover inLo slot of the dryer rear panel.
Secure oover with hold-down
screw.
Centersilver-
External
coloredterminal
Whiteneutral
ground
blockscrew
wire
connector
Green wire
Neutral
of power sllpply
grounding wire
cord or bare
(green/yellow)
copper wire
Strainrelief
4-Wire Connection
with
Frame-.Grounding
Conductor
Continue
Installation
on Page 14,
"CONNECT
EXHAUST."
Green/yellow wire
of harness
12