Install Inlet/Outlet Adapters Or Bypass Valves, Three Way Valves; Install Plastic Bypass Valve - Kenmore 300 Series Owner's Manual

Water softeners with deluxe valve
Hide thumbs Also See for 300 Series:
Table of Contents

Advertisement

Install Plastic Bypass Valve

ASSEMBLE INLET OUTLET ADAPTORS,
OR PLASTIC BYPASS VALVE
Complete the following steps to assemble the adaptors or
bypass valve.
1. Close the shutoff valve on the house main water pipe,
near the water meter or pressure tank, to turn off the
water. See Fig. 7.
2. Shut off the gas or electric supply to the water heater.
See Fig. 7.
3. Open the highest and lowest water faucets in your-
house. This will let water drain from the pipes. Close
faucets after water has drained.
4. Remove the main cover. Remove the salt hole cover
first and then pull outward on the two tabs to release
main cover. See Fig. 8.
Set both covers aside so they will not get scratched or bro-
ken.
INSTALL SEARS BYPASS VALVE AND / OR THE
INLET OUTLET THREADED ADAPTORS
NOTE: If you will not install the bypass valve because
you will have a three (3) valve bypass, skip steps 6 &
7, but do steps 5 and 8.
5. Visually check and remove any foreign materials from
the valve inlet and outlet ports. See Fig. 9. Carefully
remove the two large plastic clips (you will use them).
Check to be sure the turbine and turbine support are
firmly in place. See Fig. 10.
BYPASS VALVE:
6. Put a light coating of silicone grease on the o-ring seals
and slide onto the bypass valve.
7. Push the bypass valve into the softener valve as far as it
will go. Snap the two large holding clips into place,
from the top down as shown. See Fig. 11.
CAUTION: Be sure the clips snap firmly into place so
the bypass valve will not pull out. See Fig. 11.
INLET AND OUTLET THREADED ADAPTORS:
8. Put a light coating of silicone grease on the o-ring seals
and slide into the threaded adaptors. Push the adaptors
into the valve inlet and outlet ports, or bypass valve
ports, as far as they will go. Both adaptors are the same
and fit either port. Snap the two large holding clips
into place, as shown. See Fig. 11.
CAUTION: Be sure the clips snap firmly into place so
the tubes will not pull out. See Fig. 11.
Questions? Call The Kenmore Water Line 1-800-426-9345
Shutoff
Valve
Water
Meter
Gas
Valve
Salt Hole Cover
INSTALLING BYPASS VALVE, AND/OR
INLET AND OUTLET THREADED ADAPTORS
Valve Inlet
Shutoff
Pressure
Valve
Tank
Well
Pump
Electrical
Panel
FIG. 7
Cover (Main)
FIG. 8
Clip (2)
Valve Outlet
Included with
Softener
Included with
Softener
FIG. 9
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents