Fujitsu PRIMERGY S60 Manual page 56

Storage subsystem
Table of Contents

Advertisement

The FFx-RAID Controller Module
Description of the LED indicators
LED
7
CACHE
DAC
(yellow)
STATUS
(green)
OFF
ON
OFF
flashing
0.5 sec.
OFF
flashing
1 sec.
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
flashing
OFF
0.5 sec.
flashing
flashing
0.5 sec.
0.5 sec.
Table 8: FFx-RAID Controller Module: Status Indicators
48
8
9
DAC
POWER
ALARM
(red)
OFF
Normal operation, module ready and partner
OK
I
OFF
Normal operation, FFx-RAID controller
module not ready and partner OK.
OFF
Normal operation, FFx-RAID controller
module ready and partner failed
I
ON
Alarm:
FFx-RAID controller not powered (5 VDC;
3.3 VDC)
flashing
Alarm:
0.5 sec.
FFx-RAID controller 5 VDC failed
flashing
Alarm:
1 sec.
FFx-RAID controller 3,3 VDC failed
OFF
Cache dirty:
Data in cache and on the hard disk drives
are not identical (cache active)
OFF
Conservative Cache activated (DIP switch
K1 see "DIP Switches" on page 51)
flashing
Diagnosis Mode activated (DIP switch J1
0.5 sec.
see "DIP Switches" on page 51)
Plug-in Board Modules
Description
This signal is activated only if two
FFx-RAID controller modules are
used; only the non-defective module
can indicate that the other one has
failed.
This signal is activated only if two
FFx-RAID controller modules are
used; only the non-defective module
can indicate that the other one has
failed.
U41221-J-Z156-1-74