Fujitsu PRIMERGY S60 Manual page 25

Storage subsystem
Table of Contents

Advertisement

Operating and Indicator Elements
Optical Waveguide
Power supply status
Cooling status
V
CAUTION!
The PRIMERGY S60
storage subsystem
(without Remote Service
Board) switches OFF at
an interior temperature of
55°C (see section
"Cooling status LED lights
orange" on page 73).
Server management
status (global SES
indicator)
Table 1: Meaning of the Operating Status LEDs Indication
U41221-J-Z156-1-74
Color
Meaning
none
No mains voltage present.
green
POWER OK
Equipment switched ON, all installed
power supply units OK.
yellow
POWER WARNING
One power supply unit has failed.
orange
STANDBY
Equipment switched OFF, mains voltage
present.
green
Cooling OK
All installed fans and the interior temper-
ature are OK.
yellow
Fan warning
One fan has failed.
The temperature is OK.
orange
Cooling fault
All the fans have failed or the interior
temperature exceeds the permissible
values.
none
No status indication
orange
Identification indication
(can be activated manually from
ServerView).
For troubleshooting see section "Server
Management Status LED lights perma-
nently" on page 74.