Appendix III: IC Squared Hardware Inputs, Outputs & Indicators, Dimensions
2
To connect an IC
to the RHAON network, you first make the hardware connections, and then (if you are using CobraNet for digital audio
distribution) assign signal routing using RHAON software. You can also connect Serial Digital (AES3 aka AES/EBU) and analog audio to
2
an IC
, as well as Fault Detect and Fault Relay lines.
Master/Slave Link Cable Connectors
Overdrive LED
Flashes red when the Primary Analog Input
preamplifier is being overdriven
Flickers when an audio signal of at least -30
dBu is present at the primary analog audio
Master/Slave Setup Switches
Secondary Analog - AES/EBU Input/Output
Can be configured for "priority override"
Pins NC, W and NO; see Fault Relay below
Pins + and -; see Fault Input below for details
Remote Control Connections
For remote control from RS485 devices and
preset control using rotary switches .Pins X &
Y are for a balanced RS485 Input, Pin G is
ground. Pins G, LED & W are used for rotary
switch connections. See page 52 for details.
NOTE:
1. To prevent inadvertent operation the Mute, Volume Up & Volume Down, Input Pad and AES/EBU push buttons need to be pressed and
held down for several seconds before they activate.
2. In multi-module arrays, AC power for the array can be brought into any of the input ports; Signal cables must terminate in the input
port of the designated "Master" module.
3. IC Live IC Squared arrays include Power On/Standby control, but do not have an AC Mains power switch. Pressing the Volume Up and
Volume Down push buttons simultaneously for several seconds will toggle the array between "On" and "Standby"
64
Signal LED
input.
Fault Relay
for details
Fault Input
90/260 V AC Looping In & Out Powercon
Push-To-Reset Circuit Breakers
Fault Input
Opto-isolated input used to monitor the pres-
ence of an external wiring loop; absence of a
voltage is reported to the DSP and transmitted
to the monitoring computer over the Ethernet.
Operates on 5 to 24 V DC
Locking Connectors &
NO / NC relay contacts used to report a failure
to an external monitoring system; used mainly
to trigger a failure indication on a hard-wired
monitoring device; handles up to 0.5 Amps at
24 V AC or DC
Primary Analog -AES/EBU Input/Output
& Looping Output
XLR female; pin 1 chassis, pin 2 +, pin 3 -
Primary & Secondary Ethernet Inputs
RJ-45 female;when both are connected,
changeover to Secondary is automatic if
Primary fails. Yellow LED flashes when the
connector is active, glows steadily when data
is streaming. Green LEDs glow when con-
nected but inactive, turn Orange to indicate a
faulty connection.
Preset Controls & Readout
Mute Button
Push Button Volume Controls
Also function as a manual Standby/On
control
Input Pad & LED Indicator
On / Off 10 dB pad for Primary Analog
Input; allows input signals of up to +24
dBu when inserted
AES/EBU Input Switch
When On, turns analog input 1 into an
AES/EBU input
Power LED
Glows when amplifier power is On
Thermal LED
Lights to indicate that an over-tempera-
ture sensor has shut down the amplifier
Fault Relay