Lenovo 3057 Maintenance Manual page 59

Machine types: 3057, 3059, 3061, 3064, 3065, 3069, 3070, 3071, and 4306
Table of Contents

Advertisement

Note: The option kit for a RAID card is designed for different types of servers and might contain additional
cables that are not required for your server.
To connect cables from the RAID card to the backplane, do one of the following depending on the type of
your RAID card:
• If you are using a ThinkServer RAID 500 Adapter, do the following:
1. Use the mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
RAID card. Then, connect the mini-SAS connector
2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS
signal cable. Connect the mini-SAS connector
mini-SAS connector
• If you are using a ThinkServer RAID 700 Adapter, do the following:
1. Use one mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
the RAID card. Then, connect the mini-SAS connector
2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS signal
cable. Connect the mini-SAS connector
mini-SAS connector
• If you are using a ThinkServer RAID 710 Adapter, do the following:
1. Use the mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
RAID card. Then, connect the mini-SAS connector
2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS
signal cable. Connect the mini-SAS connector
mini-SAS connector
Figure 35. Connecting cables from the RAID card to the backplane
Refer to the following topics for information about the connector locations and the power cable connections:
"Hot-swap hard disk drive backplane" on page 40
"RAID card" on page 37
"System board components" on page 49
Connecting cables from the RAID card to the expander card, and then from the
expander card to the backplanes
To support more than eight and up to 12 3.5-inch hard disk drives or up to 16 2.5-inch hard disk drives, your
server must have a supported RAID card and an expander card installed. You need to connect cables from
the RAID card to the expander card, and then from the expander card to the backplanes.
4
to the mini-SAS ports 4-7 on the backplane.
1
to the ports 7-4 on the RAID card. Then, connect the
2
to the mini-SAS ports 4-7 on the backplane.
4
to the mini-SAS ports 4-7 on the backplane.
2
to the mini-SAS ports 0-3 on the backplane.
3
to the port 1 on the RAID card. Then, connect the
4
to the mini-SAS ports 0-3 on the backplane.
2
to the mini-SAS ports 0-3 on the backplane.
3
to the port 2 on the RAID card. Then, connect the
1
to the port 0 on the
3
to the ports 3-0 on
1
to the port 1 on the
.
Chapter 3
Product overview
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

306530593069307030714306 ... Show all

Table of Contents