Metal Prefabricated Chimney - Quadra-Fire Isle Royale 823-0170 Manual

Non-catalytic, top-load, wood heater
Table of Contents

Advertisement

When a metal prefabricated chimney is used, the manufac-
turer's installation instructions must be followed precisely.
It will be necessary to install the ceiling support package
or wall pass through, "T" section package, firestops (when
needed), insulation shield, roof flashing, chimney cap, and
any other materials deemed necessary by the instructions
of manufacturer of the prefabricated chimney. Maintain
the proper clearance to the structure as recommended by
the manufacturer. This clearance is usually a minimum of
2 inch (51mm), although it may vary by manufacturer or for
certain components. Follow the manufacturers' instructions
carefully.
There are basically two methods of metal chimney instal-
lation. One method is to install the chimney inside the
residence through the ceiling and the roof. Install an attic
insulation shield to maintain the specified clearance to insu-
lation. Insulation in this air space will cause a heat buildup
which may ignite the ceiling joists. This method of installa-
tion requires, at minimum, a ceiling support package, an
insulation shield and roof flashing. Figure 15A.
The other method is to install an exterior chimney that runs
up the outside of the residence. See Figure 15B. The
components illustrated may not look exactly like the system
you purchase, but they demonstrate the basic components
necessary for a proper and safe installation.
The chimney must be the required height above the roof or
other obstruction for safety and for proper draft operation.
The requirement is that the chimney must be at least 3 ft.
(91cm) higher than the highest point where it passes through
the roof and at least 2 ft (61cm) higher than the highest part
of the roof or structure that is within 10 ft. (305cm) of the
chimney, measured horizontally. (See page 10)
I
MPORTANT! FOLLOW MANUFACTUR-
ERS' INSTALLATION INSTRUCTIONS AND
MAINTAIN CLEARANCES AS SPECIFIED
ON PAGES 6 & 7.
In Canada, when using a factory-built chimney,
make sure it is safety listed, Type UL 103 HT
CLASS "A" or conforming to CAN/ULC-S629,
STANDARD FOR 650°C FACTORY-BUILT CHIM-
NEYS.
September 1, 2008
Isle Royale Wood Stove
CONNECTION TO A METAL PREFABRICATED CHIMNEY
Maintain 2" (51mm)
Clearance Through Eave
*
Combustible
Ceiling
Chimney
Connector
*
*
Floor
Protector
Figure 15A - Exterior Chimney
Maintain 2" (51mm)
Listed Chimney
Ceiling Support
Chimney
Connector
Floor
Protector
Figure 15B- Interior Chimney
250-5763C
Combustible Outside Wall
Listed
Listed Cap
Chimney Pipe
Chimney
Connector
Flashing
To Stove
Trim Collar
Wall Spacer on
on Inside
Outside Wall
Wall
Insulated "T"
Combustible Wall
*
Refer to Clearances to Combustibles
Listed
Chimney
Listed Cap
Combustible
Storm Collar
Ceiling
Joists
Flashing
Chimney
Connector
To Stove
Combustible Wall
*
Refer to Clearances
to Combustibles
R
2" (51mm)
Clearance
Listed Chimney
Insulated "T"
Wall Support
Attic
Insulation
Shield
Specified
Clearance
Page 15