There are several kits available to connect the stove to a
masonry fireplace. Look for a listed kit. The kit is an adapter
which is installed at the location of the fireplace damper. The
existing damper may have to be removed to allow installation
of the kit. The key points of this type of stove connection are
that the connector pipe must extend up the chimney above
where the fire clay liner starts, and the areas of the kit instal-
lation and penetration should fit tightly and be sealed with
high temperature furnace cement unless the kit's instructions
state otherwise. figure 14a. The tight fitting installation aids
the proper draw of the chimney.
Listed Rigid
Stainless Liner
Stainless Steel
Flex Section
Stainless Tee with Cleanout
Stainless Connector Pipe
Figure 14a
Page 14
R
Isle Royale Wood Stove
CONNECTION TO A MASONRY FIREPLACE
Support Plate & Clamp
NOTE: For instances with a fireplace measuring less than
30 inches in height, Hearth Legs (see Accessories on page
25) or Horizontal Flue Kit, Part 834-3790, may be ordered
to complete the masonry fireplace installation.
6
250-5763C
Fireclay liner 5/8"
(16mm) Minimum or
Equivalent.
Carry Stovepipe
Above the Liner
Damper Plate is
Removed or
Fastened in Open
Position
Use Damper Adapter or
Seal With Sheetmetal
and Sealant
Cleanout