Configuration
operation.
NOTE: Dynamic memory resilience is not supported when running Windows Server 2003,
NOTE:
NOTE:
NOTE:
SUSE SLES 9,r Red Hat RHEL AS 3, or OpenVMS in the partition.
Hardware and software memory scrubbing
Redundant DC conversion
Cell ICAP.
NOTE:
NOTE: Cell ICAP is not supported when Windows Server 2003 SUSE SLES 9, Red Hat RHEL
NOTE:
NOTE:
AS 3, or OpenVMS V8.2-1 is running in the partition. Cell iCAP support is available with
OpenVMS partitions starting with OpenVMS V8.3.
I/O
I/O: Partitions configured with dual path I/O can be configured to have no shared components
I/O
I/O
between them, thus preventing I/O cards from creating faults on other I/O paths. I/O cards in
hardware partitions (nPars) are fully isolated from I/O cards in other hard partitions. It is not
possible for an I/O failure to propagate across hard partitions. It is possible to dynamically repair
and add I/O cards to an existing running partition.
Full single-wire error detection and correction on I/O links
I/O cards fully isolated from each other
HW for the Prevention of silent corruption of data going to I/O
On-line addition/replacement (OLAR) for individual I/O cards, some external peripherals,
SUB/HUB.
NOTE: Online addition/replacement (OLAR) is not supported when running Red Hat RHEL
NOTE
NOTE
NOTE
AS 3,SUSE SLES 9, or OpenVMS in the partition.
Parity protected I/O paths
Dual path I/O
Crossbar and Cabinet Infrastructure
Crossbar and Cabinet Infrastructure
Crossbar and Cabinet Infrastructure:
Crossbar and Cabinet Infrastructure
Recovery of a single crossbar wire failure
Localization of crossbar failures to the partitions using the link
Automatic de-allocation of bad crossbar link upon boot
Redundant and hotswap DC converters for the crossbar backplane
ASIC full burn-in and "high quality" production process
Full "test to failure" and accelerated life testing on all critical assemblies
Strong emphasis on quality for multiple-nPartition single points of failure (SPOFs)
System resilience to Management Processor (MP)
Isolation of nPartition failure
Protection of nPartitions against spurious interrupts or memory corruption
Hot swap redundant fans (main and I/O) and power supplies (main and backplane power
bricks)
Dual power source
Phone-Home capability
"HA Cluster-In-A-Box" Configuration
"HA Cluster-In-A-Box" Configuration
"HA Cluster-In-A-Box" Configuration: The "HA Cluster-In-A-Box" allows for failover of users'
"HA Cluster-In-A-Box" Configuration
applications between hardware partitions (nPars) on a single Superdome system. All providers of
mission critical solutions agree that failover between clustered systems provides the safest
availability-no single points of failures (SPOFs) and no ability to propagate failures between
systems. However, HP supports the configuration of HA cluster software in a single system to allow
the highest possible availability for those users that need the benefits of a non-clustered solution,
such as scalability and manageability. Superdome with this configuration will provide the greatest
single system availability configurable. Since no single system solution in the industry provides
protection against a SPOF, users that still need this kind of safety and HP's highest availability
should use HA cluster software in a multiple system HA configuration. Multiple HA software
clusters can be configured within a single Superdome system (i.e., two 4-node clusters configured
within a 32-processor Superdome system).
HP-UX: Serviceguard and Serviceguard Extension for RAC
Windows Server 2003: Microsoft Cluster Service (MSCS) - limited configurations supported
RHEL 4 and SUSE SLES 9: Serviceguard for Linux
HP OpenVMS Cluster Software
DA - 11717
Worldwide — Version 35 — December 6, 2006
HP Integrity Superdome Servers 16- processor, 32-
HP Integrity Superdome Servers 16- processor, 32-
HP Integrity Superdome Servers 16- processor, 32-
HP Integrity Superdome Servers 16- processor, 32-
processor, and 64- processor Systems
processor, and 64- processor Systems
processor, and 64- processor Systems
processor, and 64- processor Systems
Page 25

Advertisement

loading