Table 39. Items on the Global Properties window (continued)
Support Interrupt
Restore Defaults

Accessing the Adapter Properties window

In the Adapter List window, select C1068E and press Enter. The Adapter Properties window for SAS1068E
opens.
Table 40. Items in the Adapter Properties window for SAS1068E
Adapter
PCI Slot
PCI Address (Bus/Dev)
MPT Firmware Revision
SAS Address
Status
Boot Order
Boot Support
RAID Properties
SAS Topology
Advanced Adapter Properties
Note: To make any of the settings take effect, you need to restart the server.

SAS RAID settings

In the Adapter Properties window, select RAID Properties and press Enter. The main window for SAS
RAID setup is displayed.
The following list describes the items in the main window for SAS RAID setup:
• Create IM Volume: create RAID 1 including two hard disk drives to reserve data. The default Status of the
first hard disk drive is Primary. The RAID 1 is also known as mirror image. The same data is written to the
two hard disk drives at the same time, which, however, operates as a single logical hard disk drive in
the operation system. Therefore, if one of the hard disk drives failed, the other retains a complete copy
of the data. The server can still work normally. The data can be read from the two hard disk drives at
118
ThinkServer RD240 Hardware Maintenance Manual
Item
Item
Description
Indicates the supported interrupt mode. Hook interrupt,
the Default is the default value, which supports the boot
from CD-ROM in the floppy emulation mode.
Restores the defaults.
Description
Detected SAS adapter.
The PCI slot number assigned for the adapter.
The PCI Device/Function assigned for the adapter.
Indicates the current Firmware version.
Indicates the current SAS address.
Indicates that the adapter in the boot list is enabled or
disabled.
Indicates the boot sequence.
Set the software controlling mode of the controller. The
Enabled BIOS & OS means that the adapter is controlled
by both the BIOS and the driver in the operating system.
The Enabled BIOS Only means that the adapter is
controlled only by the BIOS, instead of the driver in the
operating system. This option might not be supported by
all the operation systems, such as Windows operating
systems. The Enabled OS Only means that the adapter
is controlled only by the operating system. The Disabled
means that the adapter is disabled.
Set the Host RAID. See "SAS RAID settings" on page 118.
Set the SAS hard disk drives. See "Accessing the SAS
Topology window" on page 119.
Set the advanced properties of the adapter.