QuickSpecs

Technical Specifications

System Unit
Tower Dimensions
(HxWxD)
(with feet/bezel)
Rack Dimensions
(HxWxD)
(with bezel)
Maximum Weight
Input Requirements
(per power supply)
BTU Rating
SCSI Connectors
Power Supply Output
Power (per power
supply)
Temperature Range
Relative Humidity (non-
condensing)
Maximum Wet Bulb
Temperature
Acoustic Noise
DA - 12201 North America — Version 32 — March 30, 2007
HP ProLiant ML570 Generation 3 (G3)
20 x 11.1 x 28.8 in (50.8 x 28.2 x 73.2 cm)
11.1 x 19.0 x 28.0 in (28.2 x 48.3 x 71.1 cm)
137 lb (62.14 kg)
Range Input Voltage
Rated Input Frequency
Input Power
Rated Input Current
BTU/hr (max)
Two internal HD68 connectors (supporting Ultra320)
One external VHDCI connector (supporting Ultra320)
One SCSI knockout
Rated Steady-State
Power
Maximum Peak Power
Operating
Non-operating
Shipping
Operating
Non-operating
101.7° F (38.7° C)
Listed are the declared A-WEIGHTED SOUND POWER (LWAd) and
average bystander position A-WEIGHTED SOUND PRESSURE LEVEL
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
74, 7th edition) and declared in accordance with ISO 9296 (ECMA 109).
Idle and Operating (Maximum configuration): LWAd = 7.5 Bels, Average
Bystander LpAm = 56 dBA (Note 1)
NOTE: The values listed apply to both the tower and 6U rack
configurations. Maximum configuration tested included four Xeon MP
processors, ten SCSI hard drives, two power supplies, and six inlet
fans.
100 to 127 VAC/200 to 240 VAC
47 to 63 Hz
1163W @ 110 VAC; 1598W @ 200 VAC
12A / 8A
5457 BTU/hr
910W/1300W
960W/1420W for 10 sec max
50° to 95° F (10° to 35° C)
-20° to 140° F (-29° to 60° C)
-22° to 122° F (-30° to 50° C)
10% to 70%
5% to 95%
Page 48