The Chimney - Harman Oakwood Installation & Operating Manual

Cast iron wood stove
Table of Contents

Advertisement

Hole with minimum
clearance of 18"
(450mm) Between
connector and wall.
AN APPROVED CANADIAN WALL PASS-THROUGH
an aPProved canadian wall Pass-through

the chimney

The Oakwood must be installed into a chimney approved
for use with solid-fuel appliances. In the U.S., the Oakwood
must be connected to (1) a prefabricated chimney complying
with the requirements for Type HT chimneys in the Standard
for Chimneys, Factory-Built, Residential Type and Building
Heating Appliances, UL 103, or (2) a code-approved masonry
chimney with a tile flue liner. In Canada, the Oakwood is listed
for use with prefabricated chimneys tested and listed to the
high temperature (650 degrees C) chimney standard, ULC
S-629, or with a code approved masonry chimney.
The minimum recommended height for any chimney is 16 ft
(4.8 m) above the flue collar height. For non-mobile home
installations, a round flue (either masonry or approved
prefabricated), of either 6" (150 mm), 7" (180 mm) or 8"
(200 mm) may be used. For square or rectangular masonry
chimneys, nominal sizes of 8" x 8" or 8"x 12" (200 mm x 200
mm, 200 mm x 300 mm) may be used.
Codes require that solid-fuel chimneys extend 3 ft (0.9 m)
above the point at which they exit from the roof. The chimney
must extend 2 ft (6 m) above the highest point within a 10 ft
(3 m) radius of the top of the chimney. Thus, the 2 foot, 3 foot,
10 foot rule; "The top of the chimney must be a minimum of
3 feet above where it exits the roof, and 2 feet higher than
anything within 10 feet."
3-90-08327R26_03/14
venting
Non-combustible cover, one
side only. If two covers are
used, each must be mounted
on non-combustible spacers
at least 7/8" (21mm) away
from the wall.
1" (25mm)
Clearance
Closest Combustible Material
Minimum 12" (300) to
Combustibles
AN APPROVED U.S. WALL PASS-THROUGH
an aPProved u.s wall Pass-through
Do not connect this unit to a chimney flue servicing
another appliance.
note: the restriction of not venting more than one
appliance to the same flue applies to the U.S. specifically.
while it is not recommended that you use the same
chimney for more than one appliance, in canada certain
exceptions may be made. be sure to contact your
building code inspection official to see if this option
is allowed in your area, and to find out the specific
requirements for such an installation.
More than 10 Ft. (3 m)
10 Ft. (3 m)
2 Ft. (.6 m) Min
Ridge
Chimney
the 3-Foot, 2-Foot, 10 Foot rule
Minimum 2" (50mm)
Clearance to Brick
Liner
Minimum 12"
(50mm) to Brick
Fire Clay
Thimble
Chimney
Connector
Masonry Chimney Built to
NFPA 211 Specifications
Height necessary
above any roof surface
within 10 Ft. (3 m)
3 Ft. (.9 m) minimum
above exit point
Harman Oakwood
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oakwood cast iron wood stove

Table of Contents