Page 1
FOllOW InStruCtIOnS MaY reSult In PrOPertY daMage, bOdIlY InjurY, Or even deatH. FOr uSe In tHe u.S. and Canada. tHe OakWOOd IS nOt aPPrOved FOr MObIle HOMe InStallatIOn. IF tHIS HarMan StOve IS nOt PrOPerlY InStalled, a HOuSe FIre MaY reSult. FOr YOur SaFetY, FOllOW InStallatIOn dIreCtIOnS.
FOr MObIle HOMe InStallatIOnS Please read this entire manual before you install and use your new heating appliance. Failure to follow instructions may result in property damage, bodily injury, or even death. 352 Mountain House Road Halifax, PA 17032 U.S.A. Harman Oakwood 3-90-08327R17_10/12...
Harman Air Wash System. The Harman Oakwood has an ash pan with its own ash door that is used to remove ashes while the stove is in operation. This means you can keep one fire all winter if you desire.
SPeCIFICatIOnS 24.915" 26.235" 18.037" 21" 7.5" 30.234" 21" The Harman Oakwood meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold after July 1, 1990. Weight 440 lbs Flue Size 6 inch Log Length Recommended 21" Max Heating Capacity 2,000 sq.
Page 6
SPeCIFICatIOnS Top Load Door Optional Cooking Grill Top Load Opening Bypass Damper Control Handle Front Load Door Grate Andirons Front Load Door Latch Air Control Ash Door Ash Door Latch Harman Oakwood 3-90-08327R17_10/12...
Page 7
Ash Door Your Oakwood burns wood very efficiently. Here are To open the ash door, lift up the handle and pull out. some guidelines that will help you achieve the best Close the door by pushing in and pushing the handle performance.
Page 8
Do not burn wet wood! operating the stove. the Combustion Process Combustion in the Harman Oakwood is precisely Two important controls - the damper bypass handle controlled and is best explained in two parts. and the air control lever regulate the operation and During a wood fire, combustion air enters at the bottom output of the stove.
always wear gloves when buIldIng a FIre do not burn wet wood! operating the stove. building and Maintaining the Fire Do not use chemicals or fluids to start the fire. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up”...
Page 10
3. Inadvertently leaving the The Oakwood was designed to provide access to damper open or 4. Not keeping up with routine the ash pan without the need for opening the main maintenance, such as checking door gaskets for door.
InStallatIOn Floor Protection requirements Parallel versus Corner Installations The Oakwood must be installed on a non- A parallel installation is one in which the back and combustible floor or a non-combustible floor sides of the stove are parallel to the walls behind protector.
Page 12
InStallatIOn/ClearanCeS 21" 25" See NFPA 211 for more installation clearance reductions when using USM wall protection, etc. Harman Oakwood 3-90-08327R17_10/12...
Page 13
InStallatIOn/ClearanCeS See NFPA 211 for more installation clearance reductions when using USM wall protection, etc. Harman Oakwood 3-90-08327R17_10/12...
Page 14
InStallatIOn/ClearanCeS See NFPA 211 for more installation clearance reductions when using USM wall protection, etc. Harman Oakwood 3-90-08327R17_10/12...
Page 15
Oakwood, the stove should only be placed into the fireplace opening to the point that operation of the The Oakwood should not be installed into a factory built damper bypass control and the top load door operation fireplace unless the hearth area is designed to take the is not compromised or unsafe.
When installed and operated according to this manual, use of one or two covers as described in the diagram. the Oakwood will produce enough hot gases to keep The two other methods are described in detail in the the chimney warm so that adequate draft is maintained current issue of CAN/CSA B365, the national standard.
103, or (2) a code-approved masonry chimney with a to contact your building code inspection official tile flue liner. In Canada, the Oakwood is listed for use to see if this option is allowed in your area, and with prefabricated chimneys tested and listed to the...
Page 18
All prefabricated Oakwood. In addition to the requirements found in the chimneys must be tested to either the U.S. or Canadian previous paragraphs, it is important to be aware that high-temperature standards, UL 103 or ULC-629.
Page 19
Warning: do not install in sleeping room. to operate the stove. the air control is hot while in operation. the Harman Oakwood was tested with fuel door open and closed. keep door closed for normal operating conditions. If you operate with doors open, open the by-pass and put a screen over the opening.
Flashing roof radiation roof Factory-built Shield radiation Metal Chimney Shield attic Sealed Storm Collar radiation roof Flashing Shield Cathedral Style Chimney Support Minimum air Space Chimney with Chimney Finishing Support listing Collar Chimney Connector Chimney Connector Harman Oakwood 3-90-08327R17_10/12...
Page 21
Sheet Metal airtight Screws per joint of insulated Chimney Connector Clean- Mantel and trim Protection damper Closed and Sealed with non- Combustible Floor Protection* Material. Combustible Floor * Floor Protection in accordance with Solid Fuel appliance listing Harman Oakwood 3-90-08327R17_10/12...
Page 22
Oakwood to Flue Fireplace Conversion (Minimum nFPa 211 liner Connection) Flue liner with required airtight air Space insulated Clean-Out Stainless Steel Chimney Connector Must extend to Flue liner Minimum 8" Masonry thickness in Front of Smoke Chamber use damper adapter or Seal with non-...
Page 23
Fireplace trim Protection for reduced Clearance damper Plate removed or Fastened in Open Position use damper adapter or Seal with non- Combustible Material Floor Protection* Combustible Floor *Floor Protection in accordance with Solid Fuel appliance listing Harman Oakwood 3-90-08327R17_10/12...
Page 24
Mantel & trim Protection damper Closed and Sealed with non-Combustible Material. Floor Protection* Combustible Floor * Floor Protection in accordance with Solid Fuel appliance listing ** Check with your local building codes for clearance. Harman Oakwood 3-90-08327R17_10/12...
Remove pieces section of connector pipe from the appliance flue collar. carefully. Replace glass only with Harman replacement Carefully vacuum the ash and debris from around the glass; do not use substitutes.
(obtainable from (associated with a slow burning fire). As a result, your Harman dealer) and some are fixed in place with creosote accumulates on the flue lining. When ignited, a high temperature stove gasket cement. To change a this creosote can result in an extremely hot fire.
The rear heat shield will allow you to install your Modern homes with tight windows and doors, vapor Oakwood closer to the wall. Please note there are two barriers, and particularly with exhaust systems are the different shields based on whther the unit is rear or top most likely to require outside air.
Oakwood Service Parts beginning Manufacturing date: n/a Cast Iron Stove ending Manufacturing date: active 1-90-02490-1 (black) retired units 1-90-02490-2 (Charcoal) (ending Manufacturing date: june 2011) 1-90-02490-5 (Honey Glo) (Ending Manufacturing Date: June 2009) 1-90-02490-3 (goldenfi re) (ending Manufacturing date: june 2011) 1-90-02490-10 (Mojave red) (ending Manufacturing date: jan 2010)
Page 29
Oakwood Service Parts beginning Manufacturing date: n/a ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
Page 30
Oakwood Service Parts beginning Manufacturing date: n/a ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
Page 31
Oakwood Service Parts beginning Manufacturing date: n/a ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance...
Page 33
WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. •...
Page 34
ServICe MaIntenanCe lOg Date Of Service Performed By Description Of Service Harman Oakwood 3-90-08327R17_10/12...
Page 36
At Harman, we build each product to a standard, not a price. This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels. (Signature of Boxer) Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax, PA, USA.
Need help?