PAGING
LEVEL
ZONE ASSIGN
PAGE 1
PAGE 2
ZONE 1
ZONE 2
1 2
1 2
4
6
4
6
RMT
1&2
RMT
1&2
2
8
2
0
10
0
10
ACTIVE
ACTIVE

QUICK START

If you were the type that cheated on school book reports by just
skimming through the reading assignments, then this section is
for you! It gives you not quite enough information to really know
what you're doing. But, if you follow the recommended set up
procedure, you should get at least a "B."
Keep the amplifiers and the CP 64S turned off until all connec-
tions are made.
INTERNAL SETTINGS
Access to the following internal controls requires removal of the
top cover. All internal settings should be complete before you in-
stall the CP 64S, before you attach the power cable. The factory
default settings work for many applications. However, you may
need to change one or more for your system. See the INTERNAL
ADJUSTMENTS description on page Manual-4 for more details.
• Each Page Input has a 15 volt Phantom Power switch. The
default is off.
• The Page Priority switch assigns priority override to Page 1,
Page 2 or NO (none). The default is Page 1. If a Page has
priority, it overrides the non-priority Page in the Zone(s) it is
assigned. The NO priority setting allows the Pagers to mix.
• Each Page Input may sum with the Program Pre- or Post-
VCA. When set to Pre-VCA, Zone Level, EQ and Limiter
circuits act upon the Page. When summed Post-VCA, the
Page is not influenced by Zone Level, EQ or Limiter circuits.
The default is Pre-VCA.
• The Zone 1 Stereo/Mono switch default is Stereo.
• There are two internal trim controls for the Program Priority
detector. The Program Priority Threshold trim has a range of
-∞ to -35 dBu with a default of -50 dBu. The Program Priority
Release Time has a range of 2 to 20 seconds. The default is 12
seconds.
PAGE INPUTS
Connect Page Inputs to the Euroblock on the rear panel and
select the appropriate MIC or LINE switch position for each.
First, set the gain with the Page TRIM control, then set the Page
DETECT THRESHOLD and finally the Page Zone LEVEL.
PR 2 REMOTE
If you use the optional PR 2 remote (sold separately), wire it to
the rear RMT ZONE ASSIGN Euroblock as indicated. If you
WEAR PARTS: This product contains no wear parts.
OPERATORS MANUAL
PROGRAM INPUT LEVELS
DUCKER
PROGRAM
LINE 1
LINE 2
LINE 3
PRIORITY
DEPTH
SELECT
4
6
4
6
4
6
4
6
L1
8
2
8
2
8
2
8
2
8
OFF
ON
0
10
0
10
0
10
0
10
ZONE 1
ZONE 2
LEVEL
DUCKER
PROGRAM
LEVEL
DEPTH
SELECT
L2 L3
L2 L3
4
6
4
6
P
L1
P
2
8
2
OFF
ON
0
10
0
10
RMT
SIG
OL
RMT
SIG
OL
require remote control but do not wish to use a PR 2, any simple
switch closure to GND will work. These inputs are also TTL
compatible (0 to 5 VDC). See wiring details on page Manual-5.
PROGRAM INPUTS
Connect Program sources to the RCA PROGRAM INPUTS.
If you have a priority program, like a jukebox, connect it to the
PRIORITY Input. The Program PRIORITY ASSIGN switch
assigns priority override to Off, Zone 1, Zone 2, or Both. In the
Zone(s) that it is assigned, the priority program is automatically
selected when signal is detected.
EXPAND OUTPUTS
Wire the EXPAND OUTPUT Euroblock for each Zone as
required. These are cross-coupled line drivers and may be used
balanced or unbalanced. Each Expand Output can be Page-only,
Program-only or its Zone signal. The Zone source will not include
the Page if the Page is summed Post-VCA. Page is always avail-
able from the Page source.
ZONE OUTPUTS
Wire the two ZONE OUT Euroblocks as required. These are
cross-coupled line drivers and may be used balanced or unbal-
anced. Set the LIMIT threshold as required.
ZR 1 REMOTE
You may use one or two ZR 1 Remotes with each CP 64S. If
you use the optional ZR 1 remote (sold separately), wire it to the
rear REMOTES Euroblock as indicated. If a ZR 1 remote is not
used, any simple switch closure to ground will work for the D0
and D1 pins. These pins are TTL compatible (0 to 5 VDC). The
logic is inverse Gray Code. Any ground referenced 5 volt DC
control may be used as the input to V
Vr
or Vr
pins. See wiring details on page Manual-5.
1
2
SETUP ADVICE
The CP 64S is very versatile. While this makes a large number of
system applications possible, it also results in complexity. For this
reason, it is important to use an organized approach for setup and
calibration. A highly recommended setup procedure appears on
page Manual-7. By following it you will encounter fewer prob-
lems and reduce the need to increase our collective phone bills.
COMMERCIAL PROCESSOR
ZONE 1
+
12
6
0
8
6
12
40
100
250
630
1.6k
4k
10k
40
100
or V
1
CP 64S
ZONE 2
CP 64S
COMMERCIAL
PROCESSOR
250
630
1.6k
4k
10k
POWER
. Do not ground the
2
Manual-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP 64S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rane CP 64S

  • Page 1: Quick Start

    The default is Pre-VCA. • The Zone 1 Stereo/Mono switch default is Stereo. You may use one or two ZR 1 Remotes with each CP 64S. If you use the optional ZR 1 remote (sold separately), wire it to the •...
  • Page 2 Left and Right channels. These controls allow ±12 dB adjustment of seven ISO center frequencies on two octave centers. w POWER indicator lights when the CP 64S is connected to its needed electrical power. See q, rear panel. Manual-...
  • Page 3 A CLASS 'B' COMPUTING DEVICE. 1 PAGING INPUT Euroblock connectors may be operated balanced or unbalanced. See CP 64S Connections on page Manual-3. 2 PAGE 1 and PAGE 2 INPUT MIC / LINE switches select 30 dB Input Pads when set to LINE. Phantom Power (if enabled) is disabled when LINE is selected.
  • Page 4: Internal Adjustments

    Do this before switch is set to LINE, Phantom Power is automatically defeated. the CP 64S is installed in a rack or wired into a system. Make sure the power cable is unplugged before removing the top cover 3 Page Priority Assign allows you to select one of the Page to gain access.
  • Page 5: Remote Installation

    If a unit • Zone Level, EQ and Limiter circuits do not affect Page signals is located far from the CP 64S or is of a type that might create summed Post-VCA.
  • Page 6: Remote Mounting

    You may use 5-conductor unshielded remote to the CP 64S. Connect each wire to the Euro connector by fully control signal cable for shorter runs (less than 200 feet [60 inserting it in the correct socket and tightening the screw.
  • Page 7 RECOMMENDED CALIBRATION PROCEDURE The CP 64S is a very versatile instrument. While this allows it to conform to the requirements of a large number of system applica- tions, it also results in complexity. For this reason, it is very important to use an organized approach to system calibration. Once the internal switches are set and the system is connected, take the time for proper calibration.
  • Page 8 10. If a remote control is used, select the appropriate RMT switch settings on the front panel to verify the remote functions correctly. 11. Adjust the Equalizers as required. …You’re all set. ©Rane Corporation 00 th Ave. W., Mukilteo WA 9-09 TEL --000 FAX -- WEB www.rane.com Manual- 102907...

Table of Contents