Rane CP52S Installation Manual

Rane CP52S Installation Manual

Commercial processor
Hide thumbs Also See for CP52S:

Advertisement

Quick Links

PAGING
INPUT
DETECT
LEVEL
LIMIT
TRIM
THRESHOLD
THRESHOLD
4
6
+8
-3
+16
2
8
+30
+60
-20
+20
MIC
LINE
0
10
OL
ACTIVE
LIMIT
PROGRAM INPUT LEVELS
LINE 1
LINE 2
4
6
4
6
4
6
4
6
2
8
0
10
0
10
0
10
0
10
L2
L3
L1
P
PROGRAM SELECT
4
6
2
8
0
10
LEVEL
ZR1 Program and
Level Remote
Contents
Important Safety Instructions
Quick Start
General Description
CP52S Front Panel
CP52S Rear Panel
CP52S Connections
ZR1 Remote
Recommended Calibration Procedure
Example System: Restaurant and Lounge
Example System: Cardio Fitness Room
Technical Support
Sound System Interconnection
Block Diagram
Limited Domestic Warranty
Declaration of Conformity
The schematic is downloadable at rane.com/cp52s.html
COMMERCIAL PROCESSOR
SELECT
4
6
+8
L1
P
-3
+16
2
8
-20
+20
0
10
SCP1S Equalizer Security Cover
10
14
15
16
17
25
29
31
CP52S
INSTALLATION GUIDE
EQ
+
12
6
0
6
12
40
100
250
630
1.6k
4k
10k
2
4
5
6
7
8
8
CP52S
COMMERCIAL
PROCESSOR
POWER
22274

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP52S and is the answer not in the manual?

Questions and answers

Summary of Contents for Rane CP52S

  • Page 1: Table Of Contents

    CP52S Rear Panel CP52S Connections ZR1 Remote Recommended Calibration Procedure Example System: Restaurant and Lounge Example System: Cardio Fitness Room Technical Support Sound System Interconnection Block Diagram Limited Domestic Warranty Declaration of Conformity The schematic is downloadable at rane.com/cp52s.html 22274...
  • Page 2 • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. CAUTION: Changes or modifications not expressly approved by Rane Corporation could void the user's authority to operate the equipment. CAN ICES-3 (B)/NMB-3(B)
  • Page 3 • Consulter un revendeur ou un technicien radio / TV expérimenté. ATTENTION: Les changements ou modifications non expressément approuvés par Rane Corporation peuvent annuler l'autorité de l'utilisateur à manipuler cet équipement et rendre ainsi nulles toutes les conditions de garantie.
  • Page 4 Input. The rear panel PRIORITY switch turns priority override ON or OFF. The Priority program is automatically selected when The CP52S is very versatile. While this makes a large number of system applications possible, it also results in complexity. For this signal is detected at its Input.
  • Page 5 • Mic/Line Selection with Gain Trim The CP52S is a versatile commercial preamplifier designed for use in restaurants, bars, health clubs and offices. The CP52S • Phantom Power Switch serves one stereo Zone. One gated Paging Input and four stereo •...
  • Page 6: Line

    Graphic Equalizer controls are “stereo,” with each slider controlling the response of both Left and Right channels. These controls allow ±12 dB adjustment of seven ISO center frequencies on 1 -octave centers. y POWER indicator illuminates when the CP52S is connected to a proper power source.
  • Page 7: Program Level

    – 8 7 6 1 PAGING INPUT Euroblock connector may be wired per instructions in"CP52S Connections" on page 8. 2 MIC PHANTOM POWER switch, when ON, enables +15 volt Phantom Power to the PAGING INPUT connector. If the front panel LINE switch is selected, Phantom Power is defeated.
  • Page 8 For unbalanced operation, we recommend using two conduc- install the wiring, connect it to the remote assemblies and then tor cable with shield. The cable is wired to the CP52S the same make the final connections at the CP52S. Do not short the Vr as for balanced operation.
  • Page 9: L2 L3

    Multiconductor, unshielded CAT. #1175C ing to the CP52S. Connect each wire to the connector by fully inserting it in the correct socket and tightening the screw. Make BELDEN sure the cable jacket is stripped back sufficiently to allow it to lie Unshielded remote control signal cable CAT.
  • Page 10: Remote

    Recommended Calibration Procedure The CP52S is a very versatile instrument. While this allows it to conform to the requirements of a large number of system applica- tions, it also results in complexity. For this reason, it is very important to use an organized approach to system calibration. Once the system is connected, take the time for proper calibration.
  • Page 11: Limit Threshold +8

    Rane offers options to protect the settings you just made. To protect the equalizer section, use a Rane SCP1S security cover. To protect the setting of any rotary control, remove the knob and replace with one of the hole plugs included with the SCP1S.
  • Page 12 CP52S COMMERCIAL PROCESSOR Specifications Parameter Specification Limit Units Conditions/Comments MIC/LINE PAGING INPUT ..Input Type Balanced Instrumentation amplifier ..RFI Filter ..Gain range +30 to +60 Continuously adjustable ..Frequency Response 30 to 40k Maximum gain, +0, -3 dB ..Input Referred Noise -125 Gain: 60 dB, Rs:150 Ω, BW: 20 kHz...
  • Page 13 CP52S COMMERCIAL PROCESSOR Parameter Specification Limit Units Conditions/Comments OUTPUTS: Type Balanced Euroblock connector ..Zone Out Gain: Program In 100 kΩ load ....From Page Inputs ..Expand Out Gain: Zone 100 kΩ load ....From Page or Program In ..Frequency Response 10 to 40k +0, -3 dB ..S/N...
  • Page 14 ALL AUDIO AND REMOTES ARE CLASS 2 WIRING – MULTICHANNEL AMPLIFIER PRIORITY 1 MA 3 POWER MULTICHANNEL AMPLIFIER CHANNEL OUTPUT HEADROOM POWER -OR- From a CP64S or CP52S Expand Output PROGRAM (Page or Program) SELECT PROGRAM SELECT LEVEL LEFT RIGHT LEVEL ZONE 1 RECEPTION DISTRIBUTED LOUNGE...
  • Page 15 (ZR1) can manually change the source or volume from a wall plate, or mounted on the side of the locked equipment rack. The CP52S can stay in a secure locked rack. This protects the settings and EQ so the instructor can easily learn and know the system without surprises.
  • Page 16 RMT switch and make sure it's in the "out" position. For runs up to 200 feet any five conductor wire, 22 gauge or Then, re-test all functions of the CP52S. If all works fine now, larger, will suffice. Use shielded wire for distances greater than the problem lies in the remote or wiring to it.
  • Page 17 Rane Technical Staff RaneNote 110 © 1985, 1995, 2006, 2007, 2011, 2015 Rane Corporation Interconnection-1...
  • Page 18 Ground Loops Almost all cases of noise can be traced directly to ground ible with unbalanced. The small physical nature and short loops, grounding or lack thereof. It is important to under- cable runs of completely unbalanced systems (home audio) stand the mechanism that causes grounding noise in order also contain these ground loop noise currents.
  • Page 19 . He makes the simple point that it is absurd that Many manufacturers provide several tools for this task, you cannot go out and buy pro audio equipment from sever- including Rane. Consult your audio dealer to explore the al different manufacturers, buy standard off-the-shelf cable options available.
  • Page 20 Make sure such units are solidly grounded by tying the chassis to an earth ground using a star washer for a reliable contact. (Rane always provides this chassis point as an external screw with a toothed washer.) Any device with a 3-prong AC plug, such as an...
  • Page 21 Test & Measurement, Portland, OR, May 1992, pp. 82-92 (Audio Engineering Society, New York, 1992). 8. Macatee, RaneNote: “Grounding and Shielding Audio Devices,” Rane Corporation, 1994. 9. Philip Giddings, “Grounding and Shielding for Sound and Video,” S&VC, Sept. 20th, 1995.
  • Page 22 To Input CABLE CONNECTORS MALE ¼" BALANCED ¼" OR 3.5mm UNBALANCED RCA BALANCED BALANCED XLR TRS (TIP-RING-SLEEVE) UNBALANCED EUROBLOCK TS (TIP-SLEEVE) FEMALE BALANCED XLR – – (NOT A TRANSFORMER, SHIELD NC NOR A CROSS-COUPLED OUTPUT STAGE) – – FEMALE BALANCED XLR (EITHER A TRANSFORMER SHIELD NC OR A CROSS-COUPLED...
  • Page 23 MALE FEMALE 1=SHIELD 1=NC 2-CONDUCTOR SHIELDED CABLE 2=RED BLACK BLACK 2=RED 3=BLACK SHIELD 3=BLACK FEMALE T=RED 1=SHIELD 2=RED R=BLACK BLACK 2-CONDUCTOR SHIELDED CABLE BLACK S=NC 3=BLACK SHIELD FEMALE 1=SHIELD 1-CONDUCTOR SHIELDED CABLE T=RED 2=RED 3=NC SHIELD SHIELD S=SHIELD FEMALE 1=SHIELD 1-CONDUCTOR SHIELDED CABLE T=RED 2=RED...
  • Page 24 S=BLACK SHIELD CROSS-COUPLED OUTPUT ONLY: CONNECT BLACK TO SHIELD AT THIS END AND SET GROUND LIFT SWITCH TO ‘GROUNDED’ (IF PRESENT). ©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5000 USA TEL 425-355-6000 FAX 425-347-7757 WEB rane.com Interconnection-8 DOC 102907...
  • Page 25 CP52S COMMERCIAL PROCESSOR...
  • Page 26 CP52S COMMERCIAL PROCESSOR Block Diagram PROGRAM INPUTS PAGE ZONE EXPAND PAGE OUTPUT LINE 1 PROGRAM ZONE EXPAND LEVEL LEFT 7 BAND LINE 2 LIMIT THRESHOLD DUCK MONO -20 dBu +20 dBu INPUT SELECT RAMP PAGE (1 of 4) ZONE OUTPUT...
  • Page 27 This page intentionally left blank. Go ahead. Doodle.
  • Page 29 Rane agrees to supply all parts and labor to repair or replace defects covered by this limited warranty with parts or products of original or improved design, at its option in each respect, if the defective product is shipped prior to the end of the warranty period to any Rane authorized warranty repair facility in the U.S.
  • Page 30 New Product Registration. Fill out the warranty completely, being sure to include the model and serial number of the unit since this is how warranties are tracked. If your Rane product was purchased in the U.S.A., mail the completed card or register online with to Rane Corporation within 10 days from the date of purchase.
  • Page 31 Manufacturer: Rane Corporation Address: 10802 47th Avenue West, Mukilteo WA 98275-5000 USA This declaration is issued under the sole responsibility of Rane Corporation. The object of the declaration described above is in conformity with the relevant Union harmonisation legislation: 2014/35/EU...
  • Page 32 CP52S COMMERCIAL PROCESSOR...

Table of Contents