Download Print this page

HP ProLiant DL360 Quickspecs page 4

Generation 5
Hide thumbs Also See for ProLiant DL360:

Advertisement

QuickSpecs
Standard Features
Memory Protection &
Memory Protection &
Memory Protection &
Memory Protection &
Functionality
Functionality
Functionality
Functionality
Memory
Memory
Memory
Memory
Network Controller
Network Controller
Network Controller
Network Controller
Expansion Slots
Expansion Slots
Expansion Slots
Expansion Slots
Storage Controller
Storage Controller
Storage Controller
Storage Controller
One of the following
depending on Model
Advanced ECC (multi-bit error protection), Online Spare, Mirroring
4-way interleaving
Type
Standard (Entry or Base
Models)
Standard (Performance
Models)
Standard (Performance
Model E5345)
Maximum
NOTE:
NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) running at 1333 MHz will run at 667
NOTE:
NOTE:
MHz and in systems with a FSB running at 1066 MHz or 667 MHz the memory DIMMs will run at 533
MHz.
Two embedded NC373i Multifunction Gigabit Network Adapters with TCP/IP Offload Engine, including
support for Accelerated iSCSI through an optional Licensing Kit
Slot Number
Slot Number
Slot Number
Slot Number
Bus Speed
Bus Speed
Bus Speed
Bus Speed
1
x8 PCI Express
2
x8 PCI Express
2
64-bit/133MHz
PCI-X (option)
*NOTE:
*NOTE: Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment
*NOTE:
*NOTE:
number.
**NOTE:
**NOTE:
**NOTE:
**NOTE: Slots are enumerated differently based on OS. Microsoft OS's enumerate from lowest to
highest Device ID by bus (starting with the lowest bus).
Performance Models:
Base Models:
Entry Models:
DA - 12476
North America — Version 30 — November 14, 2007
PC2-5300 Fully Buffered DIMMs (DDR2-667)
1 GB (2 x 512 MB)
2 GB (2 x 1 GB)
4 GB (4 x 1 GB)
32 GB (8 x 4 GB)
Bus Number
Bus Number
Bus Number
Bus
Number*
11
19
16
HP Smart Array P400i/256MB BBWC Controller (RAID 0/1/1+0/5/6)
Available upgrades: 512MB memory battery-backed write cache (BBWC)
Available upgrades
Available upgrades
Available upgrades
module for RAID 0/1/1+0/5/6.
HP Smart Array P400i/256MB Controller (RAID 0/1/1+0/5)
Available upgrades
Available upgrades
Available upgrades: 512MB memory battery for battery-backed write cache
Available upgrades
(BBWC) module for RAID 0/1/1+0/5/6, or battery-backed write cache for
RAID 0/1/1+0/5/6.
HP Smart Array E200i/64MB Controller (RAID 0/1/1+0)
Available upgrades: 128MB memory battery for battery-backed write cache
Available upgrades
Available upgrades
Available upgrades
(BBWC) module for RAID 0/1/1+0/5.
HP ProLiant DL360 Generation 5 (G5)
HP ProLiant DL360 Generation 5 (G5)
HP ProLiant DL360 Generation 5 (G5)
HP ProLiant DL360 Generation 5 (G5)
Device
Device
Device
Device
Hot Plug
Hot Plug
Hot Plug
Hot Plug
Number
Number
Number
Number**
0
no
0
no
1
no
PCI Voltage
PCI Voltage
PCI Voltage
PCI Voltage
N/A
N/A
3.3 Volt
Page 4

Advertisement

loading

This manual is also suitable for:

Proliant dl360 g5